<?xml version="1.0" encoding="utf-8"?><ANNEX xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://formex.publications.europa.eu/schema/formex-05.50-20130101.xd"><BIB.INSTANCE><DOCUMENT.REF FILE="L_2013239EN.01016201.doc.xml"><COLL>L</COLL><NO.OJ>239</NO.OJ><YEAR>2013</YEAR><LG.OJ>EN</LG.OJ><PAGE.FIRST>162</PAGE.FIRST><PAGE.SEQ>1</PAGE.SEQ><VOLUME.REF>01</VOLUME.REF></DOCUMENT.REF><DATE ISO="20130802">20130802</DATE><LG.DOC>EN</LG.DOC><NO.SEQ>0004.0002</NO.SEQ><PAGE.FIRST>170</PAGE.FIRST><PAGE.SEQ>1</PAGE.SEQ><PAGE.LAST>172</PAGE.LAST><PAGE.TOTAL>3</PAGE.TOTAL></BIB.INSTANCE><TITLE><TI><P>ANNEX II</P></TI><STI><P>Ecodesign requirements</P></STI></TITLE><CONTENTS><GR.SEQ LEVEL="1"><TITLE><TI><NP><NO.P>1.</NO.P><TXT>ECODESIGN REQUIREMENTS FOR WATER HEATERS</TXT></NP></TI></TITLE><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>1.1.</NO.P><TXT><HT TYPE="BOLD">Requirements for water heating energy efficiency</HT></TXT></NP></TI></TITLE><NP><NO.P>(a)</NO.P><TXT>From <DATE ISO="20150926">26 September 2015</DATE> the water heating energy efficiency of water heaters shall not fall below the following values:</TXT><P><TBL COLS="11" NO.SEQ="0001"><CORPUS><ROW TYPE="HEADER"><CELL COL="1" TYPE="HEADER"><TXT.COL><P>Declared load profile</P></TXT.COL></CELL><CELL COL="2" TYPE="HEADER"><HT TYPE="BOLD">3XS</HT></CELL><CELL COL="3" TYPE="HEADER"><HT TYPE="BOLD">XXS</HT></CELL><CELL COL="4" TYPE="HEADER"><HT TYPE="BOLD">XS</HT></CELL><CELL COL="5" TYPE="HEADER"><HT TYPE="BOLD">S</HT></CELL><CELL COL="6" TYPE="HEADER"><HT TYPE="BOLD">M</HT></CELL><CELL COL="7" TYPE="HEADER"><HT TYPE="BOLD">L</HT></CELL><CELL COL="8" TYPE="HEADER"><HT TYPE="BOLD">XL</HT></CELL><CELL COL="9" TYPE="HEADER"><HT TYPE="BOLD">XXL</HT></CELL><CELL COL="10" TYPE="HEADER"><HT TYPE="BOLD">3XL</HT></CELL><CELL COL="11" TYPE="HEADER"><HT TYPE="BOLD">4XL</HT></CELL></ROW><ROW><CELL COL="1" TYPE="HEADER">Water heating energy efficiency</CELL><CELL COL="2"><FT TYPE="NUMBER">22</FT> %</CELL><CELL COL="3"><FT TYPE="NUMBER">23</FT> %</CELL><CELL COL="4"><FT TYPE="NUMBER">26</FT> %</CELL><CELL COL="5"><FT TYPE="NUMBER">26</FT> %</CELL><CELL COL="6"><FT TYPE="NUMBER">30</FT> %</CELL><CELL COL="7"><FT TYPE="NUMBER">30</FT> %</CELL><CELL COL="8"><FT TYPE="NUMBER">30</FT> %</CELL><CELL COL="9"><FT TYPE="NUMBER">32</FT> %</CELL><CELL COL="10"><FT TYPE="NUMBER">32</FT> %</CELL><CELL COL="11"><FT TYPE="NUMBER">32</FT> %</CELL></ROW><ROW><CELL COL="1" TYPE="HEADER">In addition, for water heaters with <HT TYPE="ITALIC">smart</HT> being declared as <QUOT.START CODE="2018" ID="QS0001" REF.END="QE0001"/>1<QUOT.END CODE="2019" ID="QE0001" REF.START="QS0001"/>: water heating energy efficiency calculated for <HT TYPE="ITALIC">smart</HT> = 0, tested under the declared load profile</CELL><CELL COL="2"><FT TYPE="NUMBER">19</FT> %</CELL><CELL COL="3"><FT TYPE="NUMBER">20</FT> %</CELL><CELL COL="4"><FT TYPE="NUMBER">23</FT> %</CELL><CELL COL="5"><FT TYPE="NUMBER">23</FT> %</CELL><CELL COL="6"><FT TYPE="NUMBER">27</FT> %</CELL><CELL COL="7"><FT TYPE="NUMBER">27</FT> %</CELL><CELL COL="8"><FT TYPE="NUMBER">27</FT> %</CELL><CELL COL="9"><FT TYPE="NUMBER">28</FT> %</CELL><CELL COL="10"><FT TYPE="NUMBER">28</FT> %</CELL><CELL COL="11"><FT TYPE="NUMBER">28</FT> %</CELL></ROW></CORPUS></TBL></P></NP><NP><NO.P>(b)</NO.P><TXT>From <DATE ISO="20170926">26 September 2017</DATE> the water heating energy efficiency of water heaters shall not fall below the following values:</TXT><P><TBL COLS="11" NO.SEQ="0002"><CORPUS><ROW TYPE="HEADER"><CELL COL="1" TYPE="HEADER"><TXT.COL><P>Declared load profile</P></TXT.COL></CELL><CELL COL="2" TYPE="HEADER"><HT TYPE="BOLD">3XS</HT></CELL><CELL COL="3" TYPE="HEADER"><HT TYPE="BOLD">XXS</HT></CELL><CELL COL="4" TYPE="HEADER"><HT TYPE="BOLD">XS</HT></CELL><CELL COL="5" TYPE="HEADER"><HT TYPE="BOLD">S</HT></CELL><CELL COL="6" TYPE="HEADER"><HT TYPE="BOLD">M</HT></CELL><CELL COL="7" TYPE="HEADER"><HT TYPE="BOLD">L</HT></CELL><CELL COL="8" TYPE="HEADER"><HT TYPE="BOLD">XL</HT></CELL><CELL COL="9" TYPE="HEADER"><HT TYPE="BOLD">XXL</HT></CELL><CELL COL="10" TYPE="HEADER"><HT TYPE="BOLD">3XL</HT></CELL><CELL COL="11" TYPE="HEADER"><HT TYPE="BOLD">4XL</HT></CELL></ROW><ROW><CELL COL="1" TYPE="HEADER">Water heating energy efficiency</CELL><CELL COL="2"><FT TYPE="NUMBER">32</FT> %</CELL><CELL COL="3"><FT TYPE="NUMBER">32</FT> %</CELL><CELL COL="4"><FT TYPE="NUMBER">32</FT> %</CELL><CELL COL="5"><FT TYPE="NUMBER">32</FT> %</CELL><CELL COL="6"><FT TYPE="NUMBER">36</FT> %</CELL><CELL COL="7"><FT TYPE="NUMBER">37</FT> %</CELL><CELL COL="8"><FT TYPE="NUMBER">37</FT> %</CELL><CELL COL="9"><FT TYPE="NUMBER">37</FT> %</CELL><CELL COL="10"><FT TYPE="NUMBER">37</FT> %</CELL><CELL COL="11"><FT TYPE="NUMBER">38</FT> %</CELL></ROW><ROW><CELL COL="1" TYPE="HEADER">In addition, for water heaters with <HT TYPE="ITALIC">smart</HT> being declared as <QUOT.START CODE="2018" ID="QS0002" REF.END="QE0002"/>1<QUOT.END CODE="2019" ID="QE0002" REF.START="QS0002"/>: water heating energy efficiency calculated for <HT TYPE="ITALIC">smart</HT> = 0, tested under the declared load profile</CELL><CELL COL="2"><FT TYPE="NUMBER">29</FT> %</CELL><CELL COL="3"><FT TYPE="NUMBER">29</FT> %</CELL><CELL COL="4"><FT TYPE="NUMBER">29</FT> %</CELL><CELL COL="5"><FT TYPE="NUMBER">29</FT> %</CELL><CELL COL="6"><FT TYPE="NUMBER">33</FT> %</CELL><CELL COL="7"><FT TYPE="NUMBER">34</FT> %</CELL><CELL COL="8"><FT TYPE="NUMBER">35</FT> %</CELL><CELL COL="9"><FT TYPE="NUMBER">36</FT> %</CELL><CELL COL="10"><FT TYPE="NUMBER">36</FT> %</CELL><CELL COL="11"><FT TYPE="NUMBER">36</FT> %</CELL></ROW></CORPUS></TBL></P></NP><NP><NO.P>(c)</NO.P><TXT>From <DATE ISO="20180926">26 September 2018</DATE> the water heating energy efficiency of water heaters shall not fall below the following values:</TXT><P><TBL COLS="4" NO.SEQ="0003"><CORPUS><ROW TYPE="HEADER"><CELL COL="1" TYPE="HEADER"><TXT.COL><P>Declared load profile</P></TXT.COL></CELL><CELL COL="2" TYPE="HEADER"><HT TYPE="BOLD">XXL</HT></CELL><CELL COL="3" TYPE="HEADER"><HT TYPE="BOLD">3XL</HT></CELL><CELL COL="4" TYPE="HEADER"><HT TYPE="BOLD">4XL</HT></CELL></ROW><ROW><CELL COL="1" TYPE="HEADER">Water heating energy efficiency</CELL><CELL COL="2"><FT TYPE="NUMBER">60</FT> %</CELL><CELL COL="3"><FT TYPE="NUMBER">64</FT> %</CELL><CELL COL="4"><FT TYPE="NUMBER">64</FT> %</CELL></ROW></CORPUS></TBL></P></NP></GR.SEQ><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>1.2.</NO.P><TXT><HT TYPE="BOLD">Requirements for storage volume of storage water heaters with declared load profiles 3XS, XXS, XS and S</HT></TXT></NP></TI></TITLE><P>From <DATE ISO="20150926">26 September 2015</DATE>:</P><LIST TYPE="alpha"><ITEM><NP><NO.P>(a)</NO.P><TXT>for storage water heaters with declared load profile 3XS the storage volume shall not exceed 7 litres;</TXT></NP></ITEM><ITEM><NP><NO.P>(b)</NO.P><TXT>for storage water heaters with declared load profiles XXS and XS, the storage volume shall not exceed 15 litres;</TXT></NP></ITEM><ITEM><NP><NO.P>(c)</NO.P><TXT>for storage water heaters with declared load profile S the storage volume shall not exceed 36 litres.</TXT></NP></ITEM></LIST></GR.SEQ><?PAGE NO='171'?><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>1.3.</NO.P><TXT><HT TYPE="BOLD">Requirements for mixed water at 40 °C of storage water heaters with declared load profiles M, L, XL, XXL, 3XL and 4XL</HT></TXT></NP></TI></TITLE><P>From <DATE ISO="20150926">26 September 2015</DATE> the amount of mixed water at 40 °C shall not fall below the following values:</P><TBL COLS="7" NO.SEQ="0004"><CORPUS><ROW TYPE="HEADER"><CELL COL="1" TYPE="HEADER"><TXT.COL><P>Declared load profile</P></TXT.COL></CELL><CELL COL="2" TYPE="HEADER"><HT TYPE="BOLD">M</HT></CELL><CELL COL="3" TYPE="HEADER"><HT TYPE="BOLD">L</HT></CELL><CELL COL="4" TYPE="HEADER"><HT TYPE="BOLD">XL</HT></CELL><CELL COL="5" TYPE="HEADER"><HT TYPE="BOLD">XXL</HT></CELL><CELL COL="6" TYPE="HEADER"><HT TYPE="BOLD">3XL</HT></CELL><CELL COL="7" TYPE="HEADER"><HT TYPE="BOLD">4XL</HT></CELL></ROW><ROW><CELL COL="1" TYPE="HEADER">Mixed water at 40 °C</CELL><CELL COL="2">65 litres</CELL><CELL COL="3">130 litres</CELL><CELL COL="4">210 litres</CELL><CELL COL="5">300 litres</CELL><CELL COL="6">520 litres</CELL><CELL COL="7"><FT TYPE="NUMBER">1040</FT> litres</CELL></ROW></CORPUS></TBL></GR.SEQ><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>1.4.</NO.P><TXT><HT TYPE="BOLD">Requirements for sound power level</HT></TXT></NP></TI></TITLE><P>From <DATE ISO="20150926">26 September 2015</DATE> the sound power level of heat pump water heaters shall not exceed the following values:</P><TBL COLS="8" NO.SEQ="0005"><CORPUS><ROW TYPE="HEADER"><CELL COL="1" COLSPAN="2" TYPE="HEADER">Rated heat output ≤ 6 kW</CELL><CELL COL="3" COLSPAN="2" TYPE="HEADER">Rated heat output &gt; 6 kW and ≤ 12 kW</CELL><CELL COL="5" COLSPAN="2" TYPE="HEADER">Rated heat output &gt; 12 kW and ≤ 30 kW</CELL><CELL COL="7" COLSPAN="2" TYPE="HEADER">Rated heat output &gt; 30 kW and ≤ 70 kW</CELL></ROW><ROW><CELL COL="1">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), indoors</CELL><CELL COL="2">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), outdoors</CELL><CELL COL="3">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), indoors</CELL><CELL COL="4">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), outdoors</CELL><CELL COL="5">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), indoors</CELL><CELL COL="6">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), outdoors</CELL><CELL COL="7">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), indoors</CELL><CELL COL="8">Sound power level (<HT TYPE="ITALIC">L<HT TYPE="SUB">WA</HT></HT>), outdoors</CELL></ROW><ROW><CELL COL="1"><FT TYPE="NUMBER">60</FT> dB</CELL><CELL COL="2"><FT TYPE="NUMBER">65</FT> dB</CELL><CELL COL="3"><FT TYPE="NUMBER">65</FT> dB</CELL><CELL COL="4"><FT TYPE="NUMBER">70</FT> dB</CELL><CELL COL="5"><FT TYPE="NUMBER">70</FT> dB</CELL><CELL COL="6"><FT TYPE="NUMBER">78</FT> dB</CELL><CELL COL="7"><FT TYPE="NUMBER">80</FT> dB</CELL><CELL COL="8"><FT TYPE="NUMBER">88</FT> dB</CELL></ROW></CORPUS></TBL></GR.SEQ><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>1.5.</NO.P><TXT><HT TYPE="BOLD">Requirements for emissions of nitrogen oxides</HT></TXT></NP></TI></TITLE><NP><NO.P>(a)</NO.P><TXT>From <DATE ISO="20180926">26 September 2018</DATE> emissions of nitrogen oxides, expressed in nitrogen dioxide, of water heaters shall not exceed the following values:</TXT><P><LIST TYPE="DASH"><ITEM><P>conventional water heaters using gaseous fuels: 56 mg/kWh fuel input in terms of <HT TYPE="ITALIC">GCV</HT>,</P></ITEM><ITEM><P>conventional water heaters using liquid fuels: 120 mg/kWh fuel input in terms of <HT TYPE="ITALIC">GCV</HT>,</P></ITEM><ITEM><P>heat pump water heaters equipped with external combustion using gaseous fuels and solar water heaters using gaseous fuels: 70 mg/kWh fuel input in terms of <HT TYPE="ITALIC">GCV</HT>,</P></ITEM><ITEM><P>heat pump water heaters equipped with external combustion using liquid fuels and solar water heaters using liquid fuels: 120 mg/kWh fuel input in terms of <HT TYPE="ITALIC">GCV</HT>,</P></ITEM><ITEM><P>heat pump water heaters equipped with an internal combustion engine using gaseous fuels: 240 mg/kWh fuel input in terms of <HT TYPE="ITALIC">GCV</HT>,</P></ITEM><ITEM><P>heat pump water heaters equipped with an internal combustion engine using liquid fuels: 420 mg/kWh fuel input in terms of <HT TYPE="ITALIC">GCV</HT>.</P></ITEM></LIST></P></NP></GR.SEQ><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>1.6.</NO.P><TXT><HT TYPE="BOLD">Requirements for product information related to water heaters</HT></TXT></NP></TI></TITLE><P>From <DATE ISO="20150926">26 September 2015</DATE> the instruction manuals for installers and end-users, free access websites of manufacturers, their authorised representatives and importers and technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:</P><LIST TYPE="alpha"><ITEM><NP><NO.P>(a)</NO.P><TXT>information identifying the model(s), including equivalent models, to which the information relates;</TXT></NP></ITEM><ITEM><NP><NO.P>(b)</NO.P><TXT>the results of the measurements for the technical parameters specified in point 6 of Annex III;</TXT></NP></ITEM><?PAGE NO='172'?><ITEM><NP><NO.P>(c)</NO.P><TXT>the results of the calculations for the technical parameters specified in point 2 of Annex IV;</TXT></NP></ITEM><ITEM><NP><NO.P>(d)</NO.P><TXT>any specific precautions that shall be taken when the water heater is assembled, installed or maintained;</TXT></NP></ITEM><ITEM><NP><NO.P>(e)</NO.P><TXT>for heat generators designed for water heaters and water heater housings to be equipped with such heat generators, their characteristics, the requirements for assembly, to ensure compliance with the ecodesign requirements for water heaters and, where appropriate, the list of combinations recommended by the manufacturer;</TXT></NP></ITEM><ITEM><NP><NO.P>(f)</NO.P><TXT>information relevant for disassembly, recycling and/or disposal at end-of-life.</TXT></NP></ITEM></LIST></GR.SEQ></GR.SEQ><GR.SEQ LEVEL="1"><TITLE><TI><NP><NO.P>2.</NO.P><TXT>ECODESIGN REQUIREMENTS FOR HOT WATER STORAGE TANKS</TXT></NP></TI></TITLE><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>2.1.</NO.P><TXT><HT TYPE="BOLD">Requirement for standing loss</HT></TXT></NP></TI></TITLE><P>From <DATE ISO="20170926">26 September 2017</DATE> the standing loss <HT TYPE="ITALIC">S</HT> of hot water storage tanks with storage volume <HT TYPE="ITALIC">V</HT>, expressed in litres, shall not exceed the following limit:</P><P><FORMULA TYPE="OUTLINE"><EXPR>16,66<OP.MATH TYPE="PLUS"/> 8,33<OP.MATH TYPE="MULT"/> V<EXPONENT>0,4</EXPONENT> Watts</EXPR></FORMULA></P></GR.SEQ><GR.SEQ LEVEL="2"><TITLE><TI><NP><NO.P>2.2.</NO.P><TXT><HT TYPE="BOLD">Requirements for product information related to hot water storage tanks</HT></TXT></NP></TI></TITLE><P>From <DATE ISO="20150926">26 September 2015</DATE> the instruction manuals for installers and end-users, the free access websites of manufacturers, their authorised representatives and importers and technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:</P><LIST TYPE="alpha"><ITEM><NP><NO.P>(a)</NO.P><TXT>information identifying the model(s), including equivalent models, to which the information relates;</TXT></NP></ITEM><ITEM><NP><NO.P>(b)</NO.P><TXT>the results of the measurements for the technical parameters specified in point 7 of Annex III;</TXT></NP></ITEM><ITEM><NP><NO.P>(c)</NO.P><TXT>any specific precautions that shall be taken when the hot water storage tank is assembled, installed or maintained;</TXT></NP></ITEM><ITEM><NP><NO.P>(d)</NO.P><TXT>information relevant for disassembly, recycling and/or disposal at end-of-life.</TXT></NP></ITEM></LIST></GR.SEQ></GR.SEQ></CONTENTS></ANNEX>