European flag

Official Journal
of the European Union

EN

C series


C/2025/2463

25.4.2025

Types of gas and the corresponding supply pressures according to Article 4(1) of Regulation (EU) 2016/426 of the European Parliament and of the Council on appliances burning gaseous fuels and repealing Directive 2009/142/EC

(This publication is based on information received by the Commission from the Member States)

(C/2025/2463)

ESTONIA

Gas Family

 

Gas Group

 

 

min

max

Gross Calorific Value (GCV) [MJ/m3]

35,53

-

Wobbe index [MJ/m3]

47,89

52,95

Gas composition by volume in % of the total content:

C1 to C5 content (sum)

-

100

N2 + CO2 content

N2 < 3 / CO2 < 2,5

CO content

-

-

Unsaturated HC content

-

-

Hydrogen content

-

0,1

Information on toxic components contained in the gaseous fuel

 

Supply pressure:

 

min

nom

max

Supply pressure at the inlet of appliances [mbar]

18

20

25

Supply pressure at the point of delivery [mbar]

18

23

25

admissible pressure loss in the end-user gas installation [mbar]

1,0

1,5

2,0

Reference conditions for Wobbe index and Gross Calorific Value (GCV)

Combustion reference temperature [°C]

15 °C

Volume measurement reference temperature [°C]

15 °C

Volume measurement reference pressure [mbar]

1 013,25 mbar

GREECE

1.   Types of gas:

The following types of gas are distributed in Greece:

—

gases in group H (2H) of the 2nd family (natural gas), and

—

gases in all three groups of the 3rd family (liquefied petroleum gas):

—

commercial butane (3B) comprising at least 85 % by mass of butane and butene, with butane as the main component;

—

commercial propane (3P) comprising at least 85 % by mass of propane and propene, with propane as the main component; and

—

a mixture of butane/propane (3P/B), also called LPG mixture, comprising propane and butane in various proportions. For example, LPG on the Greek market comprises 80 to 90 % by mass of butane and the rest of propane.

2.   Legislation:

Natural gas:

1.

Ministerial Decision No Δ3/Α΄/οικ.6598/20.03.2012 on the technical regulation on internal natural gas installations operating at pressures of up to 500mbar (Government Gazette, Series II, No 976)

2.

Amendment No Ε-143/2023 of the Management Code for the National Natural Gas System (ESFA) (9th revision) (GG II 5773)

3.

Regulation (EU) 2015/703 establishing a network code on interoperability and data exchange rules (Annex - Conversion factors between reference conditions)

Liquefied petroleum gas:

1.

Joint Ministerial Decision No 31856/11.08.2003 on the technical regulation on LPG installations in buildings (other than factories and small-scale industries) (GG II 1257)

2.

Joint Ministerial Decision No 300/2005/18.09.2006 on LPG specifications (GG II 1483).

3.   Types of gas and corresponding gas supply pressures in accordance with Article 4 of Regulation (EU) 2016/426

Gas Family

2nd Family

3rd Family

Gas Group

Group H

Group P

Group P/B

Group B

 

min

max

min

max

min

max

min

max

Gross Calorific Value (GCV) [MJ/m3]

34,75

46,70

87,48

95,40

108,72

118,80

115,92

126,36

Wobbe index [MJ/m3]

44,63

55,77

72,90

76,80

72,90

87,30

81,80

87,30

Gas composition by volume in % of the total content:

C1 to C5 content in % (sum) [% mole]

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

C1 content in % (sum) [% mole]

75

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

C4 content in % (sum) [% mole]

 (1)

 (1)

 (1)

5

 (1)

 (1)

 (1)

 (1)

C5 content in % (sum) [% mole]

 (1)

 (1)

 (1)

2

 (1)

2

 (1)

2

N2 content [% mole]

 (1)

6,0

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

CO2 content [% mole]

 (1)

3,0

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

CO content [% mole]

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

unsaturated HC content [% mole]

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

Hydrogen content [% mole]

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

Information on toxic components contained in the gaseous fuel

H2S [mg/Nm3]

 (1)

5,4  (2)

 

0

 

0

 

0

CO content [% mole]

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

 (1)

1,3-butadiene [% mole]

-

-

 (1)

0,5

 (1)

0,5

 (1)

0,5

Supply pressure:

 

min

nom

max

min

nom

max

min

nom

max

min

nom

max

Supply pressure at the point of delivery [mbar]

17

20

25

25

37

45  (3)

25

29

35  (3)

20

29

35  (3)

admissible pressure loss in the end-user gas installation [mbar]

 (1)

2,0

2,0

 (1)

2,0

2,0

 (1)

2,0

2,0

 (1)

 (1)

 (1)

Reference conditions for Wobbe index and Gross Calorific Value (GCV)

Combustion reference temperature [°C]

15 °C

Volume measurement reference temperature [°C]

15 °C

Volume measurement reference pressure [mbar]

1 013,25 mbar

HUNGARY

Gas Family

2nd Family

3rd Family

Gas Group

Group H

Group S

Group B/P

Group P

 

min

max

min

max

min

max

min

max

Gross Calorific Value (GCV) [MJ/m3]

31,46

41,01

27,94

32,6

88,52

125,81

88,52

95,65

Wobbe index [MJ/m3]

45,66

54,69

36,29

41,58

72,86

87,33

72,86

76,84

Gas composition by volume in % of the total content:

C1 to C5

content (sum)

91

100

82

86

99,6

100 [m/m%] C4:

max

60 [m/m%] C5:

max

2 [m/m%]

99,6 [m/m%]

C3:

min

95 [m/m%]

100 [m/m%] C5:

max

0,2 [m/m%]

N2 + CO2 content

0

2,5

14

18

N2 + O2 + H2: max 0,2 [m/m%]

CO content

0

0

0

0

0

0

0

0

Unsaturated HC content

0

0

0

0

mono-olefins: max 10 [m/m%]

dienes: max 0,5 [m/m%]

Hydrogen content

0

0

-

-

N2 + O2 + H2: max 0,2 [m/m%]

Information on toxic components contained in the gaseous fuel

technically free

technically free

technically free

technically free

Supply pressure:

 

min

nom

max

min

nom

max

min

nom

max

min

nom

max

Supply pressure at the inlet of appliances [mbar] (4)

18 (73 )

25 (85 )

33 (100 )

18 (73 )

25 (85 )

33 (100 )

25

(42,5 )

29 (50 )

35 (57,5 )

25 (42,5 )

29 (50 )

35 (57,5 )

Supply pressure at the point of delivery [mbar]

Value identified by the gas licensee for the connection point of the manifold system and the connecting line

admissible pressure loss in the end-user gas installation [mbar]

Depends on the make of the gas installation

Reference conditions for Wobbe index and Gross Calorific Value (GCV)

Combustion reference temperature [°C]

15 °C

Volume measurement reference temperature [°C]

15 °C

Volume measurement reference pressure [mbar]

1 013,25 mbar

MALTA

Gas Family

3rd Family

Gas Group

 

 

min

max

Gross Calorific Value (GCV) [MJ/m3]

 (5)

 (5)

Wobbe index (6) [MJ/m3]

72,9

87,3

Gas composition by volume in % of the total content:

C1

 (7)

 (7)

C2

 (7)

 (7)

C3

 (7)

 (7)

C4

 (7)

 (7)

C5

 (7)

 (7)

C6

 (7)

 (7)

N2 + CO2 content in %

 (7)

 (7)

CO content in %

 (7)

 (7)

Unsaturated HC content in %

 (7)

 (7)

Hydrogen content in %

 (7)

 (7)

Supply pressure:

 

min

nom

max

Supply pressure at the inlet of appliances [mbar]

28

-

30

Supply pressure at the point of delivery [mbar]

 (8)

 (8)

 (8)

admissible pressure loss in the end-user gas installation [mbar]

 (8)

 (8)

 (8)

SLOVAKIA

Gas Family

 

Gas Group

 

 

min

max

Gross Calorific Value (GCV) [MJ/m3]

38,5

38,9

Wobbe index [MJ/m3]

49,0

50,8

Gas composition by volume in % of the total content:

C1 to C5 content (sum)

98,2

99,2

N2 + CO2 content

0,8

1,8

CO content

n/a (9)

n/a (9)

Unsaturated HC content

n/a (9)

n/a (9)

Hydrogen content

n/a (9)

n/a (9)

Information on toxic components contained in the gaseous fuel

Information on toxic components is not available to the distribution system operator. Natural gas distributed in the territory of the Slovak Republic is odourised and does not have toxic or poisoning effects. A component – odorant – used for this purpose is toxic only to aquatic organisms.

Supply pressure:

 

min

nom

max

Supply pressure at the inlet of appliances (10) [mbar]

17

20

25

Supply pressure at the point of delivery [mbar]

n/a

n/a

n/a

admissible pressure loss in the end-user gas installation [mbar]

n/a

n/a

n/a

Reference conditions for Wobbe index and Gross Calorific Value (GCV)

Combustion reference temperature [°C]

15 °C

Volume measurement reference temperature [°C]

15 °C

Volume measurement reference pressure [mbar]

1 013,25 mbar


(1)  Not regulated.

(2)  In special circumstances and not more than 2 hours it may contain double quantity but the daily average value must be less than 6,5 mg/Nm3.

(3)  It concerns installations of liquefied petroleum gas except industrial and craft industries.

(4)  Comments:

For ‘Supply pressure at the inlet of appliances’, data in parentheses refer to elevated low pressure gas networks.

(5)  Not specified

(6)  Based on the definition of LPG found in the Liquefied Petroleum Gas Market Regulations (Legal Notice 249 of 2008) as amended

(7)  Not regulated

(8)  Not applicable

(9)  These data are not analysed by the distribution network operator and are therefore not available.

(10)  This is the input pressure for appliances that are connected to the distribution network; appliances connected to pressure vessels are also used in the Slovak Republic.


ELI: http://data.europa.eu/eli/C/2025/2463/oj

ISSN 1977-091X (electronic edition)