CINNEADH (AE) 2026/2404 ÓN gCOIMISIÚN
an 29 Deireadh Fómhair 2026
lena leasaítear Cinneadh (AE) 2021/2147 a mhéid a bhaineann le trealamh slándála eitlíochta sibhialta ar a bhfuil an mharcáil ‘Stampa AE’ a fhormheas
(Téacs atá ábhartha maidir leis an LEE)
TÁ AN COIMISIÚN EORPACH,
Ag féachaint don Chonradh ar Fheidhmiú an Aontais Eorpaigh,
Ag féachaint do Rialachán (CE) Uimh. 300/2008 ó Pharlaimint na hEorpa agus ón gComhairle an 11 Márta 2008 maidir le rialacha comhchoiteanna i réimse slándála na heitlíochta sibhialta agus lena n-aisghairtear Rialachán (CE) Uimh. 2320/2002 (1), agus go háirithe Airteagal 4(3) de,
De bharr an mhéid seo a leanas:
|
(1) |
Áirítear ar na bearta mionsonraithe maidir le cur chun feidhme na gcaighdeán bunúsach comhchoiteann dá dtagraítear in Airteagal 4(3) de Rialachán (CE) Uimh. 300/2008 nósanna imeachta maidir le trealamh slándála eitlíochta sibhialta a fhormheas agus a úsáid. |
|
(2) |
Le Rialachán Cur Chun Feidhme (AE) 2015/1998 (2) ón gCoimisiún, bunaítear córas comhchuibhithe formheasa chun trealamh slándála eitlíochta sibhialta a shuiteáil. |
|
(3) |
Maidir leis na céimeanna a glacadh chun a áirithiú go gcomhlíonann trealamh slándála eitlíochta sibhialta na caighdeáin feidhmíochta riachtanacha, rinneadh iad a chomhchuibhiú lena áirithiú go gcuirfear na bunchaighdeáin choiteanna maidir le slándáil eitlíochta chun feidhme ar an mbealach is fearr. |
|
(4) |
Aithníonn an Coimisiún gur réamhchoinníoll éigeantach é próiseas meastóireachta coiteann na Comhdhála Eorpaí um Eitlíocht Shibhialta chun trealamh slándála eitlíochta sibhialta a fhormheas. Ní thugann an Coimisiún stádas marcála sealadach ‘Stampa AE ar feitheamh’ do threalamh a dheimhnítear leis an bpróiseas meastóireachta coiteann ach i ndiaidh dó na tuarascálacha ar Leibhéal 2 a fháil. |
|
(5) |
Níor cheart go bhfaigheadh trealamh slándála atá formheasa ar an leibhéal náisiúnta, de mhaolú ar an gcóras comhchuibhithe formheasa, an mharcáil ‘Stampa AE’ go huathoibríoch. Ní fhéadfaidh an Coimisiún stádas sealadach marcála ‘Stampa AE ar feitheamh’ a thabhairt don trealamh atá formheasta ar an leibhéal náisiúnta go dtí go mbeidh na tuarascálacha tástála faighte aige. |
|
(6) |
Ba cheart don Choimisiún cinneadh a ghlacadh marcáil ‘Stampa AE’ a thabhairt do threalamh a bhfuil stádas sealadach marcála ‘Stampa AE ar feitheamh’ faighte aige. |
|
(7) |
Le Cinneadh (AE) 2021/2147 ón gCoimisiún (3) bunaítear liosta comhdhlúite de threalamh slándála eitlíochta sibhialta formheasta ar a bhfuil an stádas marcála ‘Stampa AE’ ar threalamh a dearbhaíodh le próiseas meastóireachta coiteann na Comhdhála Eorpaí um Eitlíocht Shibhialta, chun é a shuiteáil agus a úsáid ar fud an Aontais. |
|
(8) |
Ó glacadh í, d’éirigh le roinnt cumraíochtaí nua de threalamh slándála eitlíochta sibhialta dul faoi phróiseas meastóireachta coiteann na Comhdhála Eorpaí um Eitlíocht Shibhialta, agus cuireadh na tuarascálacha ábhartha Leibhéal 2 faoi bhráid an Choimisiúin a thug an stádas marcála ‘Stampa AE ar feitheamh’ ina leith. |
|
(9) |
Ba cheart, dá bhrí sin, an Iarscríbhinn a ghabhann le Cinneadh (AE) 2021/2147 a leasú trí na cumraíochtaí nua trealaimh slándála eitlíochta sibhialta ar tugadh an stádas marcála ‘Stampa AE ar feitheamh’ dóibh a chur léi. Ós rud é go meastar go ndéanann an líon gcumraíochtaí atá le cur isteach modhnú suntasach ar an Iarscríbhinn atá ann cheana, is iomchuí an Iarscríbhinn sin a ionadú. |
|
(10) |
Ba cheart don Choimisiún bunachar sonraí comhdhlúite de chuid an Aontais a choinneáil ar bun ina liostaítear trealamh a cheadaítear a shuiteáil agus a úsáid ar fud an Aontais, |
TAR ÉIS AN CINNEADH SEO A GHLACADH:
Airteagal 1
I gCinneadh (AE) 2021/2147, cuirtear an téacs atá san Iarscríbhinn a ghabhann leis an gCinneadh seo in ionad na hIarscríbhinne.
Déanfar ‘Bunachar sonraí an Aontais maidir le slándáil an tslabhra soláthair — trealamh slándála’ a thabhairt cothrom le dáta dá réir.
Airteagal 2
Tiocfaidh an Cinneadh seo i bhfeidhm an fichiú lá tar éis lá a fhoilsithe in Iris Oifigiúil an Aontais Eorpaigh.
Arna dhéanamh sa Bhruiséil, an 29 Deireadh Fómhair 2026.
Thar ceann an Choimisiúin
An tUachtarán
Ursula VON DER LEYEN
(1) IO L 97, 9.4.2008, lch. 72, ELI: http://data.europa.eu/eli/reg/2008/300/oj.
(2) Rialachán Cur Chun Feidhme (AE) 2015/1998 ón gCoimisiún an 5 Samhain 2015 lena leagtar síos bearta mionsonraithe le haghaidh chur chun feidhme na mbunchaighdeán coiteann maidir le slándáil eitlíochta (IO L 299, 14.11.2015, lch. 1, ELI: http://data.europa.eu/eli/reg_impl/2015/1998/oj).
(3) Cinneadh (AE) 2021/2147 ón gCoimisiún an 3 Nollaig 2021 maidir le trealamh slándála eitlíochta sibhialta ar a bhfuil an marcáil ‘Stampa AE’ a fhormheas (IO L 433, 6.12.2021, lch. 25). ELI: http://data.europa.eu/eli/dec/2021/2147/oj).
IARSCRÍBHINN
IARSCRÍBHINN
Liosta an trealaimh slándála eitlíochta sibhialta ar a bhfuil an mharcáil ‘Stampa AE’
1. TREALAMH BRAITE MIOTAIL A BHFÉADTAR SIÚL TRÍD (WTMD)
An trealamh WTMD ar éirigh leis sa tástáil chun an suíomh a thaispeáint, féadfar é a úsáid i gcomhar le trealamh Braite Miotail le hAghaidh Bróg agus tugtar le fios é le (SMD).
Maidir leis an measúnú ar threalamh WTMD (Caighdeán 1 agus Caighdeán 2), níl aon cheanglas ann maidir leis an uasráta rabhaidh i gcás nach bhfuil bagairt ann.
|
Aitheantóir uathúil |
Monaróir |
Ainmníocht |
Cumraíocht mhionsonraithe |
Caighdeán |
Stádas |
||||
|
Crua-earraí |
Algartam braite |
Bogearraí córais |
Crua-earraí tánaisteacha |
Coincheap na n-oibríochtaí |
|||||
|
WTMD000001 |
CEIA |
02PN10K-EVO |
02PN10K/PZ-EVO V2.00x Control Unit Board SCD73 Antenna: SS65 |
PV 1010, IS = EU-STD-2 |
n/a |
n/a |
FI060K0098v1103xUK (Quick guide) |
2.1 (SMD) |
EU Stamp |
|
WTMD000002 |
CEIA |
HI-PE PLUS |
HIPEPLUS/PZ Antenna: SS65 |
LXDA2000 |
n/a |
n/a |
FI060K0108v2300 |
2.1 (SMD) |
EU Stamp |
|
WTMD000003 |
Rapiscan |
Metor 6E |
Electronics, p/n 23106448 Antenna: Coil Set1, p/n 23109437, Coil Set2, p/n 23109438 |
Software, Detection Core, Metor 6E p/n 101021459, v1.00, EU2 |
n/a |
n/a |
CONOPS, ECAC CEP, Metor 6E, “Quick Guide”, p/n D01499, v1 |
2 |
EU Stamp |
|
WTMD000004 |
Nuctech |
MD2000 |
1.0 Antenna: MBP1-2.13 MBP2-2.13 |
08.00.06.00 |
n/a |
n/a |
V1.0 / 01-2020 |
2 |
EU Stamp |
|
WTMD000005 |
CEIA |
PMD3 Plus |
PMD3Plus/PZ Antenna: SS65 |
LXDA2000 (EU-STD-2) |
n/a |
n/a |
FI060K0108v2310 |
2.1 (SMD) |
EU Stamp |
|
WTMD000006 |
CEIA |
02PN20 |
02PN20/PZ Antenna: SS65 |
LXDA2000 (EU-STD-2) |
n/a |
n/a |
FI060K0108v2320 |
2.1 (SMD) |
EU Stamp |
|
WTMD000007 |
Garrett |
PD 6500i |
2340510 and 2340720; Antenna: 223320x and 223335x |
ECAC / SE = 162 |
n/a |
n/a |
1532010 |
2.1 |
EU Stamp |
|
WTMD000008 |
Rapiscan |
Metor 900M |
Electronics, p/n 23113530; Antenna: RX Coils, p/n 101017805, TX Coils, p/n 101017806 |
V 1.3.1, EU2 HD, Sensitivity 100 |
n/a |
n/a |
V1.0, p/n D05693 |
2 (SMD) |
EU Stamp |
|
WTMD000009 |
CEIA |
02PN20 Elliptic |
02PN20/EZ Antenna: NN76 |
LXDA2000 (EU-STD-2) |
n/a |
n/a |
FI060K0108v2400 |
2.1 (SMD) |
EU Stamp |
|
WTMD000010 |
CEIA |
PMD2 PLUS Elliptic |
PMD2PLUS/EZ Antenna: NN76 |
LXDA2000 (EU-STD-2) |
n/a |
n/a |
FI060K0108v2400 |
2.1 (SMD) |
EU Stamp |
|
WTMD000011 |
Garrett |
Paragon |
Paragon; Antenna: Panel A 223750x and Panel B 223760x |
ECAC (DSP Ver K) |
n/a |
n/a |
1557900 |
2.1 (SMD) |
EU Stamp |
2. TREALAMH BRAITE MIOTAIL LÁIMHE (HHMD)
Fágtha bán d’aonghnó
3. TREALAMH X-GHA
Fágtha bán d’aonghnó
4. TREALAMH CÓRAIS BRAITE PLÉASCÁN (EDS)
4.1 EDS le haghaidh bagáiste boilg
Ní dhearnadh tástáil ar an gcumraíocht le haghaidh acmhainneacht cosanta in aon tástáil iomlán ar cuireadh tús léi roimh an 1 Eanáir 2016.
D’fhéadfadh málaí gualainne, tobáin, gabhdáin etc. a bheith san áireamh leis an téarma ‘tráidire’.
Meastar go bhfuil Caighdeán 3 EDS bainte amach ag aon chumraíocht a chomhlíonann caighdeán 3.1 le haghaidh EDS.
|
Aitheantóir uathúil |
Monaróir |
Ainmníocht |
Cumraíocht mhionsonraithe |
Caighdeán |
Stádas |
||||
|
Crua-earraí |
Algartam braite |
Bogearraí córais |
Crua-earraí tánaisteacha |
Coincheap na n-oibríochtaí |
|||||
|
EDSHB00002 |
Smiths Detection |
XRD 3500 |
Varian MCS-7074A X-Ray Tube CANBERRA Germanium Detector |
Library “ECAC” – Nr 8.2.2.2 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00003 |
Reveal Imaging Technologies |
CT80DR |
CT80DR |
4.2.14 |
5.3.0.123 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00005 |
Smiths Detection |
CTX 9400 DSi |
CTX 9400 |
Inspection: GInsp_2.3.0 ECACa Reconstruction: Recon_2.0.2 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00006 |
Leidos |
eXaminer XLB |
10-70500-01 |
06.17 |
00.45 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00007 |
Smiths Detection |
CTX 5800 |
CTX 5800 |
Inspection: 5800 ECAC SB CB 2.17.7 Reconstruction: 3.1.2 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00008 |
Leidos |
eXaminer SX |
10-64987-01 |
5.11 |
01.01 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00010 |
Leidos |
eXaminer 3DX-ES |
1000-11700-00 |
112.3 |
8.2 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00014 |
Smiths Detection |
CTX 9800 DSi |
CTX 9800 High-Speed Configuration |
Inspection: 9800 ECAC HS CB 2.18.1 Reconstruction: 3.3.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00015 |
Smiths Detection |
CTX 5500 DS |
CTX 5500 |
Inspection: p 17_0_0 Reconstruction: trecon 3.0.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00016 |
Leidos |
eXaminer 3DX |
Part no: 200001 |
112.3 |
8.2 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00017 |
Nuctech |
XT2080 |
XT2080 |
DPC 1.1 EDS 1.1 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00018 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
07-05-00 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00019 |
Leidos |
eXaminer 3DX |
Part no: 200001 |
112.3 |
7.1 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00020 |
Leidos |
eXaminer XLB |
10-70500-01 |
06.17 |
04 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00021 |
Smiths Detection |
CTX 5800 |
CTX 5800 with Checkerboard |
Inspection: 5800 ECAC SB CB 2.18.6 Reconstruction: 5800 CB 4.0.1 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00022 |
Smiths Detection |
CTX 9800 DSi |
CTX 9800 High-Speed with Checkerboard |
Inspection: 9800 ECAC HS CB 2.18.6 Reconstruction: 9800 CB 4.0.1 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00023 |
Rapiscan |
RTT110 |
RTT110 |
1.0.22 |
8.13 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00024 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
07-20-09 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00025 |
Leidos |
eXaminer 3DX |
eXaminer 3DX |
112.5 |
10.1 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00026 |
Leidos |
eXaminer 3DX-ES |
200001 |
112.5 |
10.1 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00027 |
Leidos |
eXaminer SX |
10-64987-01 |
5.14 |
06 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00028 |
Leidos |
MV3D |
1000-10001-D1 |
7.6.2 L200 |
1.0 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00029 |
Leidos |
MV3D |
1000-10001-D1 |
7.6.2 S200 |
1.0 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00030 |
Smiths Detection |
CTX 5800 |
CTX 5800 with Checkerboard |
Inspection: 5800 ECAC SB CB 2.18.13 Reconstruction: 5800 CB 4.0.1 SC |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00031 |
Smiths Detection |
CTX 5800 |
CTX 5800 with Checkerboard |
Inspection: 5800 ECDMD SB CB 2.18.13 Reconstruction: 5800 CB 4.0.1 SC |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00033 |
Rapiscan |
RTT110 |
RTT110 |
1.0.24 |
8.13 |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00034 |
Reveal Imaging Technologies |
CT-120 |
CT-120 |
5.20.3.3 |
n/a |
On belt |
P/N 81080 Revision3 Draft |
3 |
EU Stamp |
|
EDSHB00035 |
Reveal Imaging Technologies |
CT-120 |
CT-120 |
5.20.3.5 |
n/a |
On belt |
P/N 81080 Revision3 Draft |
3 |
EU Stamp |
|
EDSHB00036 |
Smiths Detection |
CTX 9800 DSi |
CTX 9800 High-Speed with Checkerboard |
Inspection: 9800 ECAC HS CB 2.18.17 Reconstruction: 9800 CB HS 4.0.1 SC |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00037 |
Smiths Detection |
CTX 9800 DSi |
CTX 9800 High-Speed with Checkerboard Modified 605577-1, per DW 1365.2 |
Inspection: 9800 ECDMD HS CB 2.18.18 Reconstruction: 9800 CB HS 4.0.1 SC |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00039 |
Leidos |
MV3D |
1000-10001-D1 |
8.0.3 S200 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00040 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
08-27-16 |
n/a |
Tray: Crisplant Material n°: CrisBag® V5 SBT 507B595.XXX, Art. n°: 7308972 |
n/a |
3 |
EU Stamp |
|
EDSHB00041 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
08-27-16 |
n/a |
Tray: Crisplant Material n°: CrisBag® V5 LBT 507B596.XXX, Art. n°: 7308974 |
n/a |
3 |
EU Stamp |
|
EDSHB00042 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
08-27-16 |
n/a |
Tray: FRAPORT Material n°: M020745 |
n/a |
3 |
EU Stamp |
|
EDSHB00043 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
08-27-16 |
n/a |
Tray: Vanderlande Material n°: 011505-393-00001 |
n/a |
3 |
EU Stamp |
|
EDSHB00044 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
08-27-16 |
n/a |
Tray: Vanderlande Material n°: 011505-890-00001 |
n/a |
3 |
EU Stamp |
|
EDSHB00045 |
Leidos |
eXaminer XLB |
10-70500-01 |
06.27 |
04 |
Tray: Crisplant - CrisBag® V5 SBT, Art. N°: 7308972 |
n/a |
3 |
EU Stamp |
|
EDSHB00046 |
Nuctech |
XT2080AD |
XT2080AD DHV 1.0 |
OIS V2.0.004 Algorithm V3.1.18 OIS V2.0.008 Algorithm V3.1.18 |
n/a |
On belt |
V1.2 |
3 |
EU Stamp |
|
EDSHB00047 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECDMD HS CB 3.0.5 Recon Prep: LibPrep 9800 HS CB DMA 6.0.0 Reconstruction: LibRecon 9800 HS CB DMA 6.0.2 |
n/a |
Tray: Beumer / Crisplant 7308972 |
n/a |
3 |
EU Stamp |
|
EDSHB00048 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECDMD HS CB 3.0.5 Recon Prep: LibPrep 9800 HS CB DMA 6.0.0 Reconstruction: LibRecon 9800 HS CB DMA 6.0.2 |
n/a |
Tray: Vanderlande long 011531-727-00001 |
n/a |
3 |
EU Stamp |
|
EDSHB00049 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECDMD HS CB 3.0.5 Recon Prep: LibPrep 9800 HS CB DMA 6.0.0 Reconstruction: LibRecon 9800 HS CB DMA 6.0.2 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00050 |
Leidos |
MV3D |
1000-10001-D1 |
8.4.6 L200 |
n/a |
Tray: Vanderlande SBT, Item No. 011505-890-00001 |
n/a |
3 |
EU Stamp |
|
EDSHB00051 |
Nuctech |
XT2100 |
XT2100 DHV 1.0 |
OIS V2.0.004 Algorithm V3.1.22 OIS V2.0.008 Algorithm V3.1.22 OIS V2.0.004 Algorithm V3.1.23 OIS V2.0.008 Algorithm V3.1.23 |
n/a |
On belt |
CONOPS: V1.2 |
3 |
EU Stamp |
|
EDSHB00052 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.0 Recon Post: Postproc SC 8.0.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00053 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECAC HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.0 Recon Post: Postproc SC 8.0.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00054 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.0 Recon Post: Postproc SC TUB 8.0.0 |
n/a |
Tray: Beumer / Crisplant 400B767 |
n/a |
3 |
EU Stamp |
|
EDSHB00055 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
08-28-19 |
n/a |
Trays: Crisplant CrisBag NG Tray V3 part n°: 400B767 and 419B629 |
n/a |
3 |
EU Stamp |
|
EDSHB00056 |
SureScan |
x1000 |
x1000 – HiSpeed (Stationary Gantry) |
4.0.0 |
n/a |
On belt |
x1000B-i1310-A01 - x1000 Scanner Operations Manual, x1000B-i1310-B00 - x1000 Scanner Operations Manual |
3 |
EU Stamp |
|
EDSHB00057 |
Reveal Imaging Technologies |
CT-120 |
CT-120 |
5.20.3.11 |
n/a |
On belt |
P/N 81080 Revision3 Draft |
3 |
EU Stamp |
|
EDSHB00058 |
Reveal Imaging Technologies |
CT-120 |
CT-120 |
5.20.3.12 |
n/a |
On belt |
P/N 81080 Revision3 Draft |
3 |
EU Stamp |
|
EDSHB00059 |
Reveal Imaging Technologies |
CT-120 |
CT-120 |
5.20.3.13 |
n/a |
On belt |
P/N 81080 Revision3 Draft |
3 |
EU Stamp |
|
EDSHB00060 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECAC HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.2 Recon Post: Postproc SC 8.0.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00061 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.2 Recon Post: Postproc SC 8.0.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00062 |
Leidos |
MV3D |
1000-10001-D1 |
8.5.2 L200 |
n/a |
Tray: Crisplant CrisBag V5 SBT, Art. N°7308972 |
n/a |
3 |
EU Stamp |
|
EDSHB00064 |
Smiths Detection |
CTX 5800 |
CTX 5800 |
Inspection: 5800 ECAC SB EDM 3.0.16 Reconstruction: 9.1.1 Recon Post: 9.1.1 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00065 |
Leidos |
MV3D |
1000-10001-D1 |
8.5.4 L200 |
n/a |
Tray: Fraport AG, Art. N°M020745 |
n/a |
3 |
EU Stamp |
|
EDSHB00066 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.0 XT2100HS DHV 1.1 |
OIS V2.0.008 Algorithm V3.1.26 |
n/a |
On belt |
XT2100HS CONOPS v4.0 |
3 |
EU Stamp |
|
EDSHB00067 |
Smiths Detection |
CTX 9800 Dsi (0.5 m/s configuration) |
1003589-02 |
Inspection: 9800 ECAC UHS EDM 3.0.18 Reconstruction: 9.2.0 Recon Post: 9.2.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00068 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) |
4.6.0 |
n/a |
On belt |
x1000B-i1310-A01 - x1000 Scanner Operations Manual, x1000B-i1310-B00 - x1000 Scanner Operations Manual |
3.1 |
EU Stamp |
|
EDSHB00069 |
Leidos |
MV3D |
1000-10001-D1 |
8.9.6 L200 |
n/a |
Tray: Crisplant CrisBag V5 LBT, Art. N°7308974 |
n/a |
3 |
EU Stamp |
|
EDSHB00070 |
Leidos |
MV3D |
1000-10001-D2 |
8.9.4 N200 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00071 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
09-21-09 |
n/a |
Tray: BigBear BBF11012 |
n/a |
3 |
EU Stamp |
|
EDSHB00072 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.0 XT2100HS DHV 1.1 |
Algorithm V3.1.27 |
n/a |
Tray: Beumer CrisBag V5 SBT Art No. 7308972; Vanderlande tote No. 011505-393-00001 |
XT2100HS CONOPS v4.0 |
3 |
EU Stamp |
|
EDSHB00073 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.0 |
Algorithm V3.1.32 |
n/a |
Tray: AENA.MAD-01 |
XT2100HS_CONOPS_v3.5_20181115 |
3 |
EU Stamp |
|
EDSHB00074 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.0 XT2100HS DHV 1.1 |
V3.1.28.2 |
n/a |
On belt |
XT2100HS CONOPS v4.0 |
3.1 |
EU Stamp |
|
EDSHB00075 |
Nuctech |
XT2100-R |
XT2100-R DHV 1.0 |
Algorithm V3.1.27 |
n/a |
Tray: Beumer CrisBag® tote No. 843139000, Vanderlande tote No. 011505-393-00001 |
V1.0 |
3 |
EU Stamp |
|
EDSHB00076 |
Leidos |
MV3D |
1000-10001-D1 |
9.0.4 S100 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00077 |
Leidos |
MV3D |
1000-10001-D1 |
9.0.4 S200 |
n/a |
Tray: Crisplant CrisBag® V3 SBT, Art. No. 400B767 |
n/a |
3 |
EU Stamp |
|
EDSHB00078 |
Leidos |
MV3D |
1000-10001-D1 |
9.0.5 S100 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00079 |
Leidos |
MV3D |
1000-10001-D1 |
9.1.2 L200 |
n/a |
Tray: Vanderlande, Item No. 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 |
n/a |
3 |
EU Stamp |
|
EDSHB00080 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
09-21-09 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00081 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
09-47-17 |
n/a |
On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00082 |
Smiths Detection |
CTX 9800 Dsi (0.5 m/s configuration) |
1003589-03 |
Inspection: 9800 ECAC UHS EDM 3.1.17 Reconstruction: 9.2.0 Recon Post: 9.2.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00083 |
Smiths Detection |
CTX 9800 Dsi (0.5 m/s configuration) |
1003589-03 |
Inspection: 9800 ECAC UHS EDM 3.2.0 Reconstruction: 9.2.0 Recon Post: 9.2.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00084 |
Smiths Detection |
CTX 9800 Dsi (0.5 m/s configuration) |
1003589-03 |
Inspection: 9800 ECAC UHS EDM 3.2.1 Reconstruction: 9.2.0 Recon Post: 9.2.0 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00085 |
Smiths Detection |
CTX 9800 Dsi (0.3 m/s configuration) |
CTX 9800 DSi (0.3 m/s configuration) |
Inspection: ECAC HS EDM 3.1.4 Reconstruction: 9.2.0 Recon Post: 9.3.3 |
n/a |
On belt |
n/a |
3 |
EU Stamp |
|
EDSHB00086 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry); (200000009900B ASSY, TOP LEVEL) |
4.6.1 |
n/a |
On belt |
x1000B-i1310-C00 - x1000 Scanner Operations Manual |
3.1 |
EU Stamp |
|
EDSHB00087 |
Smiths Detection |
CTX 9800 Dsi (0.5 m/s configuration) |
CTX 9800 Dsi (0.5 m/s configuration) |
Inspection: 9800 ECAC UHS EDM 3.1.17 Reconstruction: 9.2.0 Recon Post: 9.3.6 |
n/a |
Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 |
n/a |
3 |
EU Stamp |
|
EDSHB00088 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
09-21-09 |
n/a |
Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 |
n/a |
3 |
EU Stamp |
|
EDSHB00089 |
Smiths Detection |
CTX 9800 DSi |
MD Checkerboard HS Configuration |
Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.2 Recon Post: Postproc SC TUB 8.0.0 |
n/a |
Tray: Beumer / Crisplant 400B767 |
n/a |
3 |
EU Stamp |
|
EDSHB00090 |
Leidos |
MV3D |
1000-10001-D1 |
9.7.5 L100 |
n/a |
On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00091 |
Smiths Detection |
CTX 9800 Dsi (0.5 m/s configuration) |
CTX 9800 DSi Comet x-ray tube (0.5 m/s configuration) |
Inspection: 9800 ECDMD UHS EDM 3.6.0 Reconstruction: 9.2.0 Recon Post: 9.2.0 |
n/a |
On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00092 |
Rapiscan |
RTT110 |
RTT110 |
1.0.47 |
8.14 |
Bigbear Tray (ref: BBF11012) |
n/a |
3 |
EU Stamp |
|
EDSHB00093 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.0 XT2100HS DHV 1.1 |
Algorithm V3.1.30 |
n/a |
On belt |
CONOPS XT2100HS v4.0 |
3.1 |
EU Stamp |
|
EDSHB00094 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.0 XT2100HS DHV 1.1 |
Algorithm V3.1.31 |
n/a |
On belt |
CONOPS XT2100HS v4.0 |
3.1 |
EU Stamp |
|
EDSHB00095 |
Nuctech |
XT2100HS |
DHV 1.1 |
Algorithm v3.1.36 |
n/a |
Daifuku (P/N BTSP0007001C) |
CONOPS XT2100HS v4.0 |
3.1 |
EU Stamp |
|
EDSHB00096 |
Rapiscan |
RTT110 |
RTT110 |
1.4.04 |
8.14 |
On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00097 |
Nuctech |
XT2100HS |
DHV 1.1 |
Algorithm V3.1.39 |
n/a |
Vanderlande (P/N 011505-706-00001) |
CONOPS XT2100HS V4.0 |
3.1 |
EU Stamp |
|
EDSHB00099 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
09-63-09 |
n/a |
Tray: AENA.MAD-001 On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00100 |
Smiths Detection |
CTX 9800 DSi (0.5 m/s configuration) |
CTX 9800 DSi Comet x-ray tube (0.5 m/s configuration) |
Inspection: 9800 ECDMD UHS EDM 3.6.2 Reconstruction: 9.2.0 Recon Post: 9.2.0 |
n/a |
On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00101 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.0 XT2100HS DHV 1.1 |
Algorithm v3.1.37 |
n/a |
Beumer CrisBag V5 SBT Art No. 7308972; Vanderlande Tote 850 (P/N 011505-393-00001); Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 |
CONOPS XT2100HS V4.0 |
3.1 |
EU Stamp |
|
EDSHB00102 |
Nuctech |
XT2100HS |
DHV 1.1 |
V3.1.40 |
n/a |
Beumer CrisBag V3 SB art.no.419B629.XXX |
CONOPS XT2100HS V4.0 |
3.1 |
EU Stamp |
|
EDSHB00103 |
Rapiscan |
RTT110 |
RTT110 |
EDS v1.0.50 |
8.14 |
On belt Daifuku Logan BTSP0007001A BigBear BBF11012 |
n/a |
3 |
EU Stamp |
|
EDSHB00104 |
Leidos |
MV3D |
1000-10001-D2 |
10.1.2 H100 |
n/a |
On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00105 |
Rapiscan |
RTT110 |
RTT110 |
EDS 1.0.64 |
8.14 |
Tray: Beumer Crisbag V5 SBT No. 7308972 |
n/a |
3 |
EU Stamp |
|
EDSHB00106 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) |
5.5.0.0 |
n/a |
Tray: Vanderlande No. 001036-103-00001 |
x1000B-i1310-C01 |
3 |
EU Stamp |
|
EDSHB00107 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) |
5.5.0.1 |
n/a |
Tray: Vanderlande No. 001036-103-00001 |
x1000B-i1310-C01 |
3.1 |
EU Stamp |
|
EDSHB00108 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) |
5.5.0.1 |
n/a |
Tray: CrisBag® V5 SBT 507B595.XXX |
x1000B-i1310-C01 |
3 |
EU Stamp |
|
EDSHB00109 |
Nuctech |
WooKong H |
WooKong H DHV 2.0 |
V3.1.47 |
n/a |
On belt |
V2.0 (30-11-2020) |
3 |
EU Stamp |
|
EDSHB00110 |
Nuctech |
WooKong H DHV 2.0 |
WooKong H DHV 2.0 |
V3.1.49 |
n/a |
On belt |
V2.0 (30-11-2020) |
3.1 |
EU Stamp |
|
EDSHB00111 |
Rapiscan |
RTT110 |
RTT110 |
EDS 1.0.64 |
8.14 |
Tray: Vanderlande OBT Tote No. 001036-278-00001 |
n/a |
3 |
EU Stamp |
|
EDSHB00112 |
Rapiscan |
RTT110 |
RTT110 |
1.0.67 |
8.14 |
On belt; HKIA Utility tray Rapiscan P/N 101038931; Rapiscan Standard Utility tray P/N 101049996 Utz Bekon tray 3-122. 7000.xxxx; TTP 238/959 tray Rapiscan P/N 101038932; Daifuku Logan tray BTSP0007001A; Big Bear tray BBF11012 Beumer Crisbag V5 SBT No. 7308972 |
RTT ECAC ConOps V1.0 8 Sept 2020 |
3 |
EU Stamp |
|
EDSHB00113 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.1 |
v3.1.57 |
n/a |
Tray: Siemens (80 2002 514) |
XT2100HS v3.5a |
3.1 |
EU Stamp |
|
EDSHB00114 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.1 |
v3.1.56 |
n/a |
Tray: AENA.SPC-01 Tray: Congost-FT-80401 |
XT2100HS v3.5a |
3.1 |
EU Stamp |
|
EDSHB00115 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) |
5.6.0.1 |
n/a |
On belt; Tray Beumer OOG 2600 x 900 P/N 40002507913 |
x1000-i1310-D00 |
3 |
EU Stamp |
|
EDSHB00116 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) |
5.6.0.2 |
n/a |
On belt |
x1000-i1310-D00 |
3.1 |
EU Stamp |
|
EDSHB00117 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
09-63-09 |
n/a |
Beumer CrisBag NG Tray V3 (P/N 419B629); Beumer CrisBag V5 LBT (P/N 507B596) |
n/a |
3 |
EU Stamp |
|
EDSHB00118 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.1 |
v3.1.51 |
n/a |
On belt |
XT2100HS CONOPS v4.0 |
3.1 |
EU Stamp |
|
EDSHB00119 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
10-33-00 |
n/a |
Tray: Beumer CrisBag NG Tray V3 (P/N 419B629); Tray: Beumer CrisBag V5 LBT (P/N 507B596); Tray: Vanderlande Wanne Leipzig |
n/a |
3.1 |
EU Stamp |
|
EDSHB00120 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
10-32-00 |
n/a |
Tray: AENA.MAD-001; Tray: Vanderlande Ref: 001036-241-00002; Tray: Vanderlande Ref: 001036-103-00001 Rev B01; Tray: Vanderlande Ref: 001036-103-00001 Rev C01; On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00121 |
Nuctech |
WooKong H |
WooKong H DHV 2.1 |
V3.1.60 |
n/a |
Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 |
V3.0 |
3.1 |
EU Stamp |
|
EDSHB00122 |
Nuctech |
WooKong H |
WooKong H DHV 2.1 |
V3.1.61 |
n/a |
Tray: Vanderlande OBT (P/N: 001036-278-00001) |
V3.0 |
3.1 |
EU Stamp |
|
EDSHB00123 |
Nuctech |
WooKong H |
WooKong H DHV 2.1 |
V3.1.62 |
n/a |
On belt |
V3.0 |
3.1 |
EU Stamp |
|
EDSHB00124 |
Nuctech |
XT2100HS |
XT2100HS DHV 3.0 |
V3.1.58 |
n/a |
On belt |
XT2100HS CONOPS v4.0 |
3.1 |
EU Stamp |
|
EDSHB00125 |
Nuctech |
XT2100L |
XT2100L DHV 1.0 |
V3.1.58 |
n/a |
On belt |
XT2100L v1.0 |
3.1 |
EU Stamp |
|
EDSHB00127 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) 200000009900B |
5.8.0.2; 5.8.0.5 |
n/a |
Beumer OOG 2600 x 900 (P/N 40002507913) |
x1000-i1310- D00 |
3.1 |
EU Stamp |
|
EDSHB00128 |
SureScan |
x1000 (0.5 m/s configuration) |
x1000 – HiSpeed.5 (Stationary Gantry) 200000009900B |
5.8.0.5 |
n/a |
Beumer CrisBag V5 SBT (P/N 507B595.XXX) |
x1000-i1310-D00 |
3.1 |
EU Stamp |
|
EDSHB00129 |
Nuctech |
XT2100HS |
XT2100HS DHV 1.1 |
v3.1.38 |
n/a |
AENA.MAD-01 |
XT2100HS_CONOPS_v3.5_20181115 |
3.1 |
EU Stamp |
|
EDSHB00131 |
Leidos |
MV3D |
1000-10001-D2 |
10.1.2 H100 |
n/a |
Tray: Leidos 1600mm (0190-40545-00); Tray: Big Bear BBF11012 (0190-40703-00) |
n/a |
3 |
EU Stamp |
|
EDSHB00132 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
10-34-00 |
n/a |
Tray: Siemens Logistics S-Tray, No.80.2002.514-00, Rev. G and H.;Tray: Beumer CrisBag 5 SBT Antistatic (P/N 7325131); Tray: Beumer CrisBag 5 LBT Antistatic (P/N 7325132) |
n/a |
3.1 |
EU Stamp |
|
EDSHB00133 |
Smiths Detection |
HI-SCAN 10080 XCT |
HS 10080 XCT |
10-40-00 |
n/a |
Tray: On belt; Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01; Tray: AENA.MAD-001; Tray: Beumer CrisBag NG Tray V3 |
n/a |
3.1 |
EU Stamp |
|
EDSHB00134 |
Analogic |
SeleCT |
10-79611-02 |
12.02.30 |
n/a |
n/a |
16-120373 |
3.1 |
EU Stamp |
|
EDSHB00135 |
Analogic |
SeleCT |
10-79611-02 |
12.02.34 |
n/a |
BigBear P/N BBF11012; Beumer CrisBag OBTL. Article No. 10468579; Beumer CrisBag 5 SBT Article No. 7308972 |
16-120373 |
3.1 |
EU Stamp |
|
EDSHB00136 |
Smiths Detection |
SDX 10080 SCT |
SDX 10080 SCT; SDX 10080 SCT LS |
60-10-00 |
n/a |
On belt |
n/a |
3.1 |
EU Stamp |
|
EDSHB00137 |
Nuctech |
WooKong G |
DHV 1.0 |
V3.1.68 |
n/a |
On belt |
V1.0 |
3.1 |
EU Stamp |
4.2 EDS le haghaidh bagáiste cábáin
Braitheann coincheap na n-oibríochtaí a chuirtear i bhfeidhm maidir le EDS le haghaidh trealamh bagáiste cábáin ar an gcaighdeán atá bainte amach.
Caighdeán C1: is gá leictreonaic agus leachtanna, aerasóil, agus glóthaigh (LAGanna) a dhífheistiú chun scagadh a dhéanamh.
Caighdeán C2: ceadaítear bagáiste ina bhfuil ríomhairí so-ghluaiste agus ítimí móra leictreacha eile a scagadh leis.
Caighdeán C3: ceadaítear bagáiste ina bhfuil ríomhairí so-ghluaiste agus ítimí móra leictreacha eile agus LAGanna a scagadh leis.
Caighdeán C4: an coincheap céanna oibríochtaí le Caighdeán C3.
|
Aitheantóir uathúil |
Monaróir |
Ainmníocht |
Cumraíocht mhionsonraithe |
Caighdeán |
Stádas |
||||
|
Crua-earraí |
Algartam braite |
Bogearraí córais |
Crua-earraí tánaisteacha |
Coincheap na n-oibríochtaí |
|||||
|
EDSCB00001 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-12-23 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00002 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
200.3.0 |
n/a |
MacDonald Humfrey tray: (P/N 12043-SLT) |
CONOPS 1 SRT |
C2 |
EU Stamp |
|
EDSCB00003 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
200.3.0 |
n/a |
Daifuku tray: SSL01_XA001_NH |
CONOPS 1 SRT |
C2 |
EU Stamp |
|
EDSCB00004 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.2.5 |
n/a |
Herbert tray: 91280AS |
8100-26282-OM |
C2 |
EU Stamp |
|
EDSCB00005 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.2.5 |
n/a |
MacDonald Humfrey tray: (P/N 12043-SLT) |
8100-26282-OM |
C2 |
EU Stamp |
|
EDSCB00006 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.2.5 |
n/a |
Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) |
8100-26282-OM |
C2 |
EU Stamp |
|
EDSCB00007 |
Smiths Detection |
HI-SCAN 6040-2is HR |
6040-2is HR |
09-15-17 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00008 |
Smiths Detection |
HI-SCAN 6040-2is HR |
6040-2is HR |
09-15-17 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00009 |
Smiths Detection |
HI-SCAN 6040-2is HR |
6040-2is HR |
09-15-20 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00010 |
Smiths Detection |
HI-SCAN 6040-2is HR |
6040-2is HR |
09-15-19 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00011 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-12 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00012 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-13 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00013 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-16-23 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C2 |
EU Stamp |
|
EDSCB00014 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-16-23 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C2 |
EU Stamp |
|
EDSCB00015 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-12 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00016 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-13 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00017 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-15-14 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00018 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-15-14 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00019 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-15-16 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00020 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-16-26 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
C2 |
EU Stamp |
|
EDSCB00021 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-17-16 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00022 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-17-26 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
C2 |
EU Stamp |
|
EDSCB00023 |
Smiths Detection |
XDi |
XDi |
XDi-CBS-C-v1.0 |
n/a |
MacDonald Humfrey Tray (P/N 34460689) |
2.13 |
C1 |
EU Stamp |
|
EDSCB00024 |
Analogic |
ConneCT |
n/a |
9.04 |
n/a |
Daifuku tray (P/N 21-06027-01) |
16-01519 Rev.00-2016 |
C2 |
EU Stamp |
|
EDSCB00025 |
Smiths Detection |
HI-SCAN 6040-2is HR |
6040-2is HR |
09-15-20 |
n/a |
Smiths Detection Tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00026 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-16-23 |
n/a |
Smiths Detection Tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) |
95595885 (2016/09/26) |
C2 |
EU Stamp |
|
EDSCB00027 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
201.1.1 |
n/a |
MacDonald Humfrey tray (P/N 12043-SLT) |
Detect 1000 user guide Revision 3.0 |
C2 |
EU Stamp |
|
EDSCB00028 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
201.1.1 |
n/a |
Daifuku tray: SSL01_XA001_NH |
Detect 1000 user guide Revision 3.0 |
C2 |
EU Stamp |
|
EDSCB00029 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.4.14 |
n/a |
Herbert tray: 91280AS |
8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00030 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.4.15 |
n/a |
Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) |
8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00031 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.4.18 |
n/a |
MacDonald Humfrey tray (P/N 12043-SLT) |
8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00032 |
Nuctech |
Kylin |
DHV 1.0 |
v3.5.7 |
n/a |
Vanderlande Scannojet Tray v4 P10128 revA |
v1.0 |
C1 |
EU Stamp |
|
EDSCB00033 |
Nuctech |
Kylin |
DHV 1.0 |
v3.5.9 |
n/a |
Vanderlande Scannojet Tray v4 P10128 revA |
v1.0 |
C1 |
EU Stamp |
|
EDSCB00034 |
Analogic |
ConneCT |
ConneCT |
9.07 |
n/a |
Daifuku tray (P/N 21-06027-01) |
16-01519 Rev.00-2016 |
C2 |
EU Stamp |
|
EDSCB00035 |
Gilardoni |
FEP ME 640 AMX |
37548400-001 |
3AUE0294-005 |
n/a |
Gilardoni Tray (P/N 55203181) |
37640500-001 37640500-004 |
C1 |
EU Stamp |
|
EDSCB00036 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-10-00 |
n/a |
MacDonald Humfrey tray (P/N 34460689) |
95596016 (2017/09/26) |
C2 |
EU Stamp |
|
EDSCB00037 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-18-13 |
n/a |
MacDonald Humfrey tray (P/N 34460689) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00038 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-18-24 |
n/a |
MacDonald Humfrey tray (P/N 34460689) |
95595885 (2016/09/26) |
C2 |
EU Stamp |
|
EDSCB00039 |
Rapiscan |
920CT |
n/a |
9.04 |
n/a |
Daifuku tray (P/N 21-06027-01) |
101014944 Rev 2 |
C2 |
EU Stamp |
|
EDSCB00040 |
Rapiscan |
920CT |
n/a |
9.07 |
n/a |
Daifuku tray (P/N 21-06027-01) |
101014944 Rev 2 |
C2 |
EU Stamp |
|
EDSCB00041 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-14-00 |
n/a |
Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) |
95596016 (2017/09/26) |
C1 |
EU Stamp |
|
EDSCB00042 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-14-00 |
n/a |
Smiths Detection tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) |
95596016 (2017/09/26) |
C1 |
EU Stamp |
|
EDSCB00043 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-20-00 |
n/a |
MacDonald Humfrey tray (P/N 34460689) |
95596016 (2017/09/26) |
C2 |
EU Stamp |
|
EDSCB00044 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-20-00 |
n/a |
Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) |
95596016 (2017/09/26) |
C1 |
EU Stamp |
|
EDSCB00045 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-20-00 |
n/a |
Smiths Detection tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) |
95596016 (2017/09/26) |
C1 |
EU Stamp |
|
EDSCB00046 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
314.0.1 |
n/a |
MacDonald Humfrey tray: (P/N 12043-SLT) |
Detect 1000 user guide Revision 3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00047 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
314.0.1 |
n/a |
Daifuku tray: SSL01_XA001_NH |
Detect 1000 user guide Revision 3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00048 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
205.0.0 |
n/a |
Daifuku tray: SSL01_XA001_NH |
Detect 1000 user guide Revision 3.0 |
C2 |
EU Stamp |
|
EDSCB00049 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
205.0.0 |
n/a |
MacDonald Humfrey tray: (P/N 12043-SLT) |
Detect 1000 user guide Revision 3.0 |
C2 |
EU Stamp |
|
EDSCB00050 |
Nuctech |
CX6040D |
CX6040D |
Eda V1.0.0 |
n/a |
Nuctech NUC680 tray (P/N v1) |
CONOPS CX6040D V1.0 |
C1 |
EU Stamp |
|
EDSCB00051 |
Nuctech |
CX6040D |
CX6040D |
Eda V1.0.0 |
n/a |
Vanderlande Scannojet tray v4 P10128 RevA |
CONOPS CX6040D V1.0 |
C1 |
EU Stamp |
|
EDSCB00052 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-27-00 |
n/a |
MacDonald Humfrey tray (P/N 34460689) |
95596016 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00053 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-27-00 |
n/a |
Smiths Detection tray P/N 34486990); Smiths Detection tray 2 (P/N 34482148) Smiths Detection tray 2 (P/N 34506084) |
95596016 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00054 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-19-23 |
n/a |
Vanderlande Scannojet tray (P/N 10128 / 095527-727) |
95596016 |
C1 |
EU Stamp |
|
EDSCB00055 |
Analogic |
ConneCT |
ConneCT |
9.07 |
n/a |
Herbert tray (P/N 42112482) |
16-01519 Rev.03-2018 |
C2 |
EU Stamp |
|
EDSCB00056 |
Analogic |
ConneCT |
ConneCT |
9.11 |
n/a |
Vanderlande tray (P/N 095527-727) |
16-01519 Rev.03-2018 |
C2 |
EU Stamp |
|
EDSCB00057 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.4.25 |
n/a |
MacDonald Humfrey tray: (P/N 12043-SLT) |
8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00058 |
Leidos |
ClearScan |
1000-10001-CS |
EDS_1.4.25 |
n/a |
Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) |
8100-26282-OM |
C3 |
EU Stamp |
|
EDSCB00059 |
Nuctech |
Kylin Ti |
DHV 1.0 |
v3.6.10 |
n/a |
Nuctech NUC680 tray (P/N v1) |
Kylin Ti v1.0 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00060 |
Rapiscan |
620DV |
n/a |
4.517 |
n/a |
MacDonald Humfrey tray (P/N 101005244) |
D00370 Rev.1 |
C1 |
EU Stamp |
|
EDSCB00061 |
Rapiscan |
920CT |
n/a |
9.07 |
n/a |
Herbert tray (P/N 42112482) |
101014944 Rev 2 |
C2 |
EU Stamp |
|
EDSCB00062 |
Rapiscan |
920CT |
n/a |
9.11 |
n/a |
Vanderlande tray (P/N 095527-727) |
101014944 Rev 2 |
C2 |
EU Stamp |
|
EDSCB00063 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-31-00 |
n/a |
Smiths Detection tray (P/N 34486990) |
95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00064 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-30-00 |
n/a |
MacDonald Humfrey tray (P/N 34460689) |
95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00065 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-30-00 |
n/a |
Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) |
95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00066 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-30-00 |
n/a |
Smiths Detection tray (P/N 34486990) |
95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00067 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-31-00 |
n/a |
Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) |
95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00068 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-31-00 |
n/a |
MacDonald Humfrey tray (P/N 34460689) |
95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00069 |
Smiths Detection |
HI-SCAN 6040-2is HR |
6040-2is HR |
09-19-19 |
n/a |
Vanderlande tray (P/N P10128 / 095527-727) |
95596016 (2017/09/26) |
C1 |
EU Stamp |
|
EDSCB00070 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-13 |
n/a |
Smiths Detection tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) |
95595885 (2016/09/26) |
C1 |
EU Stamp |
|
EDSCB00071 |
Analogic |
ConneCT |
ConneCT |
9.15.01 |
n/a |
Vanderlande tray (P/N 095527-727) |
16-01519 Rev.03-2018 |
C2 |
EU Stamp |
|
EDSCB00072 |
Analogic |
ConneCT |
ConneCT |
9.15.01 |
n/a |
Herbert tray (P/N 42112482) |
16-01519 Rev.03-2018 |
C2 |
EU Stamp |
|
EDSCB00073 |
Analogic |
ConneCT |
ConneCT |
9.15.01 |
n/a |
MacDonald Humfrey tray (P/N 12043-SLT) |
16-01519 Rev.03-2018 |
C2 |
EU Stamp |
|
EDSCB00074 |
Analogic |
ConneCT |
ConneCT |
9.17.02 |
n/a |
Herbert tray (P/N 42112482) |
16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00075 |
Analogic |
ConneCT |
ConneCT |
9.17.02 |
n/a |
MacDonald Humfrey tray (P/N 12043-SLT) |
16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00076 |
Analogic |
ConneCT |
ConneCT |
v9.17.01 |
n/a |
Vanderlande tray (P/N 095527-727) |
16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00077 |
Nuctech |
Kylin MV |
DHV 1.0 |
v7.0.3 |
n/a |
Vanderlande Scannojet Tray v4 P10128 revA |
EDSCB and LEDS V2.0 |
C2 |
EU Stamp |
|
EDSCB00078 |
Nuctech |
Kylin MV |
DHV 1.0 |
v7.0.3 |
n/a |
Nuctech NUC680 tray (P/N v1) |
EDSCB and LEDS V2.0 |
C2 |
EU Stamp |
|
EDSCB00079 |
Nuctech |
Kylin Ti |
DHV 1.0 |
v3.6.10 |
n/a |
Vanderlande Scannojet Tray v4 P10128 revA |
Kylin Ti v1.0 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00080 |
Rapiscan |
920CT |
n/a |
9.15.01 |
n/a |
Herbert tray (P/N 42112482) |
101014944 Rev 2 |
C2 |
EU Stamp |
|
EDSCB00081 |
Rapiscan |
920CT |
n/a |
9.15.01 |
n/a |
Vanderlande tray (P/N 095527-727) |
101014944 Rev 2 |
C2 |
EU Stamp |
|
EDSCB00082 |
Rapiscan |
920CT |
n/a |
9.15.01 |
n/a |
MacDonald Humfrey tray (P/N 12043-SLT) |
101014944 Rev 2 |
C2 |
EU Stamp |
|
EDSCB00083 |
Rapiscan |
920CT |
n/a |
9.17.02 |
n/a |
Herbert tray (P/N 42112482) |
101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00084 |
Rapiscan |
920CT |
n/a |
9.17.02 |
n/a |
MacDonald Humfrey tray (P/N 12043-SLT) |
101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00085 |
Rapiscan |
920CT |
n/a |
9.17.01 |
n/a |
Vanderlande tray (P/N 095527-727) |
101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00086 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-70-23 |
n/a |
Vanderlande Scannojet tray (P/N P10128 / 095527-727) |
95596016 |
C2 |
EU Stamp |
|
EDSCB00087 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
326.0.0 |
n/a |
Tray: VanDerLande Bandeja Scannojet |
Mfg. No. 1000D1000v4.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00088 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-30-00 |
n/a |
Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) Vanderlande (P10128 / 095527-727) |
95596016 Rev.1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C2 and C3 |
EU Stamp |
|
EDSCB00089 |
Analogic |
ConneCT |
ConneCT |
9.19.04 |
n/a |
Herbert (P/N 42112482) MacDonald Humfrey (P/N 12043-SLT) Vanderlande (P/N 095527-727) |
16-01519-rev03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00090 |
Rapiscan |
920CT |
n/a |
9.19.04 |
n/a |
Herbert tray (P/N 42112482) MacDonald Humfrey tray (P/N 12043-SLT) Vanderlande tray (P/N 095527-727) |
101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00091 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-36-00 |
n/a |
Smiths tray (P/N 34486990) Mac Donald Humfrey (P/N34460689) Daifuku (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) |
95596016 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00092 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-41-00 |
n/a |
Smiths (P/N 34486990) Mac Donald Humfrey (P/N34460689) Daifuku (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) |
95596016 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00093 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
326.0.0 |
n/a |
OneTray Tray (P/N OT_VAS007) OneTray (P/N OT-VAS013) OneTray (P/N OT-VAS015) OneTray (P/N OT-VAS016) |
IDSS_REP-077_Detect1000_ConOps_Rev0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00094 |
Nuctech |
CX7555D |
CX7555D.A03N |
GEC 1.0.2 |
n/a |
Nuctech NUC680 tray (P/N v3); Vanderlande Scannojet tray 95527-727 (P10128 revA); MacDonald Humfrey tray (12043-SLT) |
CONOPS_CX7555D_EDSCB_V1.0_20190716 |
C1 |
EU Stamp |
|
EDSCB00095 |
Leidos |
ClearScan HS |
1000-10001-CSU |
EDS-1.4.33 |
n/a |
Vanderlande (P/N 095527-727) |
8100-34802 OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00096 |
Leidos |
ClearScan HS |
1000-10001-CSU |
EDS-1.4.41 |
n/a |
MacDonald Humfrey tray (P/N 12043-SLT) |
8100-34802 OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00097 |
Leidos |
ClearScan HS |
1000-10001-CSU |
EDS-1.4.42 |
n/a |
Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) |
8100-34802 OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00098 |
SureScan |
Detect 1000 |
Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) |
329.0.0 |
n/a |
Herbert tray (P/N 91280AS) |
Mfg. No. 1000D1000v4.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00099 |
SureScan |
Detect 1000 |
Detect 1000 |
332.1.0 |
n/a |
Cassioli tray (P/N S030012FPLT) WO tray (P/N W-280819-000) |
IDSS_REP-077_Detect1000_ConOps_Rev0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00100 |
Nuctech |
Kylin Ti |
Kylin Ti DHV 1.0 |
v3.6.12 |
n/a |
Nuctech NUC680 tray (P/N v3) |
Kylin Ti CONOPS v1.2 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00101 |
Nuctech |
Kylin Ti |
Kylin Ti DHV 1.0 |
v3.6.13 |
n/a |
Cassioli tray (P/N S030008FPLT) |
Kylin Ti CONOPS v1.2 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00102 |
Smiths Detection |
HI-SCAN 6040-2is HR |
6040-2is HR |
09-15-20 |
n/a |
Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373) Smiths Detection tray 3 (P/N 34496512) |
95596016 rev. 02 (2020/03/01) |
C1 |
EU Stamp |
|
EDSCB00103 |
Analogic |
ConneCT |
ConneCT |
v9.23.05 |
n/a |
Herbert tray (P/N 101019470) |
16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00104 |
Analogic |
ConneCT |
ConneCT |
v9.21.09 |
n/a |
Vanderlande tray (P/N 095527-727) |
16-01519 Rev.03-2018 |
C3 |
EU Stamp |
|
EDSCB00105 |
Analogic |
ConneCT |
ConneCT |
v9.23.04 |
n/a |
MacDonald Humfrey (P/N 12043-SLT) |
16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00106 |
Nuctech |
Kylin Ti |
DHV 2.0 |
V3.6.23 |
n/a |
Alfyma tray (P/N RDBA18-PART-000-B) Vanderlande Scannojet tray (P/N 095527-727 / P10128 revA) MacDonald Humfrey tray (P/N 12043-SLT) |
Kylin Ti - CONOPS v1.2 (2019/07/03) Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00107 |
Rapiscan |
920CT |
920CT |
v9.23.05 |
n/a |
Herbert tray (P/N 101019470) |
101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00108 |
Rapiscan |
920CT |
920CT |
v9.21.09 |
n/a |
Vanderlande tray (P/N 095527-727) |
101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00109 |
Rapiscan |
920CT |
920CT |
v9.23.04 |
n/a |
MacDonald Humfrey (P/N 12043-SLT) |
101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00110 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; CTiX Model S |
20-50-00 |
n/a |
OneTray tray (P/N OT_VAS013) Cassioli tray (P/N S030012FPLT) Smiths Detection tray 3 (P/N 34496512) Smiths Detection tray 3 (P/N 34493797) Smiths Detection tray 3 (P/N 34495373) |
95596016 rev.02 (2020/03/01) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00111 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-71-27 |
n/a |
Smiths Detection tray (P/N 34486990) |
95596016 (2017/09/26) |
C2 |
EU Stamp |
|
EDSCB00112 |
Rapiscan |
920DX |
920DX |
1.22 |
n/a |
Herbert tray (P/N 42112482); Vanderlande tray (P/N 095527-727); MacDonald Humfrey tray (P/N 101005244) |
D05150 rev1, 920DX ConOps EDSCB C1 |
C1 |
EU Stamp |
|
EDSCB00113 |
Rapiscan |
920DX |
920DX |
1.23 |
n/a |
Herbert tray (P/N 42112482); Vanderlande tray (P/N 095527-727) |
D05150 rev1, 920DX ConOps EDSCB C1 |
C1 |
EU Stamp |
|
EDSCB00114 |
Rapiscan |
920DX |
920DX |
1.25 |
n/a |
MacDonald Humfrey tray (P/N 101005244) |
D05150 rev1, 920DX ConOps EDSCB C1 |
C1 |
EU Stamp |
|
EDSCB00115 |
Nuctech |
Kylin MV |
DHV 1.0 |
v7.0.5 |
n/a |
NUC680 tray (P/N v3) |
EDSCB and LEDS V2.0 |
C2 |
EU Stamp |
|
EDSCB00116 |
Nuctech |
CX6040D |
CX6040D |
Eda V1.0.0 |
n/a |
OneTray (P/N VAS021); MacDonald Humfrey tray (12043-SLT); NUC680 tray (P/N v5) |
CONOPS_CX6040D_V1.0_EDSCB |
C1 |
EU Stamp |
|
EDSCB00117 |
Nuctech |
Kylin Ti |
DHV 2.0 |
V3.6.25 |
n/a |
NUC680 tray (P/N v3) |
Kylin Ti CONOPS v1.2; Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00118 |
Nuctech |
Kylin Ti |
DHV 2.0 |
V3.6.27 |
n/a |
Cassioli tray (P/N S030008FPLT) |
Kylin Ti CONOPS v1.2; Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00119 |
Smiths Detection |
HI-SCAN 6040 DV |
6040DV |
30-00-25 |
n/a |
Vanderlande tray (P/N 10128 / 095527-727); Smiths Detection tray 3 (SD3, P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512) |
95596016 rev. 02 (2020/03/01) |
C1 |
EU Stamp |
|
EDSCB00120 |
Smiths Detection |
HI-SCAN 6040 DV |
6040DV |
30-00-38 |
n/a |
Smiths Detection tray 2 (SD2, P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (SD3, P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512) |
95596016 rev. 02 (2020/03/01) |
C1 |
EU Stamp |
|
EDSCB00121 |
Nuctech |
CX6040D |
CX6040D |
Eda V1.0.4 |
n/a |
Cassioli tray (P/N S030008FPLT); NUC680 tray (P/N V2); NUC680 tray (P/N V3) |
CONOPS CX6040D V1.0 |
C1 |
EU Stamp |
|
EDSCB00122 |
Smiths Detection |
HI-SCAN 7555 DV |
7555 DV |
30-10-16 |
n/a |
Smiths Detection tray 2 (SD2, P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (SD3, P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512) |
95596016 |
C1 |
EU Stamp |
|
EDSCB00123 |
Smiths Detection |
HI-SCAN 7555 DV |
7555 DV |
30-10-17 |
n/a |
Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512); Schoeller Allibert tray 2A021(P/N 11112352) |
95596016 |
C1 |
EU Stamp |
|
EDSCB00124 |
Nuctech |
Kylin Ti |
DHV 1.0 |
v3.6.8 |
n/a |
Nuctech NUC680 tray (P/N v1); Vanderlande Scannojet tray (P/N 095527- 727 / P10128 revA) |
Kylin Ti CONOPS v3.0 |
C2 |
EU Stamp |
|
EDSCB00125 |
Nuctech |
AX6040 |
A01N |
GEC 3.0.2 |
n/a |
NUC680 V3 |
v 1.0 |
C2 |
EU Stamp |
|
EDSCB00126 |
Nuctech |
AX6040 |
A01N |
GEC 3.0.7 |
n/a |
NUC680 V5 |
v 1.0 |
C2 |
EU Stamp |
|
EDSCB00127 |
SSTLabs |
E3S 690 |
E3S 690 |
1.4.2 |
n/a |
EV tray |
SSQP-06-027 Rev No. 4 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00128 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-71-00 |
n/a |
Cassioli tray (P/N S030012FPLT); OneTray tray (P/N OT_VAS013); Smiths Detection tray 3 (P/N 34496512); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373) |
95596016 - LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 2000 ml |
C3 |
EU Stamp |
|
EDSCB00129 |
Nuctech |
Kylin Ti |
DHV 2.0 |
V3.6.30 |
n/a |
NUC680 tray (P/N v5); OneTray (P/N VAS013) |
Kylin Ti CONOPS v1.2; Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
|
EDSCB00130 |
Leidos |
PX 640 DV |
37548400-001 |
3AUE0294-005 |
n/a |
Leidos tray (P/N AX0190-42132-00) |
37640500-004 |
C1 |
EU Stamp |
|
EDSCB00131 |
Leidos |
ClearScan HS |
AX1000-10001-CSU |
1.4.60 |
n/a |
Cassioli (P/N: S030012FPLT) |
AX8100-34802-OM - LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml |
C3 |
EU Stamp |
5. TEILGEAN ÍOMHÁNNA BAGRACHA (TIP)
Fágtha bán d’aonghnó
6. TREALAMH BRAITE RIANTA PLÉASCACHA (ETD)
Maidir le feidhmiú trealaimh EDT, rinneadh measúnú ar dhá mhodh samplála le linn an mheasúnuithe:
|
— |
Ciallaíonn (H) gur éirigh leis an trealamh sna tástálacha le mapaireacht láimhe; |
|
— |
Ciallaíonn (W) gur éirigh leis an trealamh sna tástálacha le mapaireacht fleisce. |
Maidir le feidhmiú trealaimh EDT, rinneadh measúnú ar dhá réimse úsáide le linn na measúnuithe:
|
— |
Ciallaíonn (P) gur éirigh leis an trealamh sna tástálacha maidir le scagadh a dhéanamh ar phaisinéirí, daoine nach paisinéirí iad, ítimí ar iompar, bagáiste cábáin agus bagáiste boilg; |
|
— |
Ciallaíonn (C) gur éirigh leis an trealamh sna tástálacha maidir le scagadh a dhéanamh ar lastas agus post, soláthairtí eitilte, soláthairtí aerfoirt agus ábhair aeriompróra a luchtaítear i mbolg an aerárthaigh. |
Maidir le cumas braite trealaimh ETD, úsáidtear an tásc seo a leanas:
|
— |
Ciallaíonn (G1) an trealamh ETD a bhfuil an caighdeán braite ceimiceán G1 bainte amach aige, sa bhreis ar an gcaighdeán braite pléascán a baineadh amach roimhe sin.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
7. TREALAMH CÓRAIS BRAITE PLÉASCÁN LEACHTACH (LEDS)
Ar bhonn choincheap na n-oibríochtaí arna soláthar ag an monaróir, rinneadh feidhmiú LEDS a thástáil le haghaidh cineál áirithe oibríochtaí:
|
— |
Ciallaíonn (A) go ndéanann LEDS coimeádáin aonair a scagadh agus ceanglaítear leis na coimeádáin a oscailt lena sampláil; |
|
— |
Ciallaíonn (B) go ndéanann LEDS coimeádáin aonair a scagadh agus ní cheanglaítear leis na coimeádáin a oscailt; |
|
— |
Ciallaíonn (C) go ndéanann LEDS coimeádáin éagsúla a scagadh agus ní cheanglaítear leis na coimeádáin a oscailt. |
Nuair a úsáidtear trealamh de chineál A, B nó C, ní mór coimeádáin LAG a bhaint de bhagáiste cábáin agus scagadh a dhéanamh orthu ar leithligh.
|
— |
Ciallaíonn (D) go ndéanann LEDS coimeádáin LAG a scagadh agus ní cheanglaítear leis na coimeádáin a oscailt (ní bhristear an séala bunaidh); |
|
— |
Ciallaíonn (D+) gur féidir le LEDS scagadh a dhéanamh ar choimeádáin LAG freisin agus leictreonaic chasta (e.g. ríomhairí glúine) i láthair i mbagáiste cábáin. |
Nuair a úsáidtear trealamh de chineál D nó D+, ní gá coimeádáin LAG a bhaint de bhagáiste cábáin.
|
Aitheantóir uathúil |
Monaróir |
Ainmníocht |
Cumraíocht mhionsonraithe |
Caighdeán |
Stádas |
||||
|
Crua-earraí |
Algartam braite |
Bogearraí córais |
Crua-earraí tánaisteacha |
Coincheap na n-oibríochtaí |
|||||
|
LEDS000001 |
Kromek |
Identifier BLS-1003 |
n/a |
CMP_SOF_0800 Rev 4 |
n/a |
n/a |
MAL-OPS-0851 |
2 (B) |
EU Stamp |
|
LEDS000002 |
Nuctech |
LS1516BA |
DHV 1.0 |
AV 3.1.0.9 |
V1.2.026.140 |
n/a |
2010-06-01 CONOPS-V1-C |
2 (B) |
EU Stamp |
|
LEDS000003 |
Smiths Detection |
HI-SCAN 6040aTiX |
n/a |
05-92-30 |
n/a |
n/a |
95592934, 10/08/2010 |
2 (C) |
EU Stamp |
|
LEDS000004 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
05-93-30 |
n/a |
n/a |
95592934, 10/08/2010 |
2 (C) |
EU Stamp |
|
LEDS000005 |
Veriteque USA, Inc |
SwabTek LETK |
Test strip batch 200710 |
n/a |
n/a |
n/a |
July 2010 |
2 (A) |
EU Stamp |
|
LEDS000006 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
06-31-07 |
n/a |
n/a |
95592934, 10/08/2010 |
2 (C) |
EU Stamp |
|
LEDS000007 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
06-31-35 |
n/a |
n/a |
95592934, 10/08/2010 |
2 (C) |
EU Stamp |
|
LEDS000008 |
Agilent Technologies |
Insight100 |
INS100-v1.0 |
INS100-27 Rev. 1.0, 1 Sep 2011 |
Insight.exe (2.0.0.1) Insight100.exe (2.2.1.0) |
Spectrograph: Q22244 CCD: DR-324B-FI |
INS100-26 Rev. 1.0, 7 Sep 2011 |
3 (B) |
EU Stamp |
|
LEDS000009 |
Agilent Technologies |
Insight100 |
INS100-v1.0 |
INS100-27 Rev. 1.1, 1 Oct 2011 |
Insight100.exe (2.1.0.0) Insight100.exe (2.2.1.0) |
Spectrograph: Q22244 CCD: DR-324B-FI |
INS100-26 Rev. 1.0, 7 Sep 2011 |
2 (B) |
EU Stamp |
|
LEDS000010 |
Optosecurity |
OptoScreener on Smiths 6040i |
Smiths 6040i |
6.0 |
n/a |
OS-3000 |
D500-10001 |
2 (C) |
EU Stamp |
|
LEDS000011 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
06-41-38 |
n/a |
n/a |
95592934, 20/09/2011 |
2 (C) |
EU Stamp |
|
LEDS000012 |
Reveal Imaging Technologies |
CT-800 |
CT-800 |
4.3.0.2 |
n/a |
n/a |
CT-800 User Guide (P/N 81032) |
2 (D) |
EU Stamp |
|
LEDS000013 |
Emisens |
EMILI |
EMILI 2 |
Database 7.1 ECAC_Retest_Jan2012_v3.ini |
n/a |
n/a |
Emili2_ConOP_03; Rev. 2.0 July 2011 |
2 (B) |
EU Stamp |
|
LEDS000014 |
Emisens |
EMILI |
EMILI 2 |
Database 7.3 ECAC_Retest_Jan2012_v3.ini |
n/a |
n/a |
Emili2_ConOP_03; Rev. 2.0 July 2011 |
2 (B) |
EU Stamp |
|
LEDS000015 |
Gilardoni |
FEP ME 640 |
05141092 |
n/a |
3AUE0217 |
OptoScreener OS3000 System 5.8; Software: 5.8.0.42386 5.8.6.53192 Acquisition module 6.0; Liquid detection module 6.3 |
37300500-005 |
2 (C) |
EU Stamp |
|
LEDS000016 |
Gilardoni |
FEP ME 640 AMX |
05141082 |
n/a |
3AUE0183 |
OptoScreener OS3000 System 5.8; Software: 5.8.0.42386 5.8.6.53192 Acquisition module 6.0; Liquid detection module 6.3 |
37300500-005 |
2 (C) |
EU Stamp |
|
LEDS000017 |
Rapiscan |
620 DV |
620DV |
3.280 |
n/a |
Rapiscan Tray (P/N 42106376 |
92106913 rev 1 |
2 (C) |
EU Stamp |
|
LEDS000018 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
06-60-30 |
n/a |
Schoeller Allibert tray 2A021 |
95593780, 30/03/2012 |
2 (C) |
EU Stamp |
|
LEDS000019 |
Battelle |
LS10 |
LS10 (635109J5000-10) |
v1.3.14.1026 |
n/a |
Firmware v1.24 |
LS10 Operator Manual (635109J0040) |
2 (B) |
EU Stamp |
|
LEDS000020 |
Battelle |
LS10 |
LS10 (635109J5000-10) |
v1.3.20.1045 |
n/a |
Firmware v1.24 |
LS10 Operator Manual (635109J0040) |
2 (B) |
EU Stamp |
|
LEDS000021 |
Analogic |
COBRA |
AN6980 |
Config 4.192 (261) |
n/a |
n/a |
1-64812 |
2 (D) / (D+) |
EU Stamp |
|
LEDS000022 |
Analogic |
COBRA |
AN6980 |
Config 4.193 (261) |
n/a |
n/a |
1-64812 |
2 (D) / (D+) |
EU Stamp |
|
LEDS000023 |
CEIA |
EMA-3 |
EMA-3 |
PV EMA3 3540, PVCT EMAO 2100 |
n/a |
n/a |
FI200K0015v1116UK |
3 (B) |
EU Stamp |
|
LEDS000024 |
FLIR |
PaxPoint V2 |
n/a |
Beta 1.00 |
n/a |
n/a |
20.08.2010 with one additional page concerning specific sampling for type A tests |
3 (A) |
EU Stamp |
|
LEDS000025 |
Thermo Fisher Scientific |
TruScreen 580-1281 |
n/a |
V2.1.0/Build 9119/Conf BLSM-A1-T03E |
n/a |
n/a |
Brochure TSCBR02 with one additional page |
3 (A) |
EU Stamp |
|
LEDS000026 |
Kromek |
Identifier BLS-1006 |
SPF-TEC-1207 |
7.4.0.0 |
n/a |
BOM-OPS-1006 |
CON-OPS-0866 Rev3 |
2 (B) |
EU Stamp |
|
LEDS000027 |
Smiths Detection |
HI-SCAN 6040i |
91520001 |
06-82-37 |
n/a |
TIM (Threat Inquest Module) |
95594060 |
2 (C) |
EU Stamp |
|
LEDS000028 |
Smiths Detection |
HI-SCAN 6046si |
91150001 |
06-82-38 |
n/a |
TIM (Threat Inquest Module) |
95594060 |
2 (C) |
EU Stamp |
|
LEDS000029 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
06-31-36 |
n/a |
n/a |
95592934, 20/09/2011 |
2 (C) |
EU Stamp |
|
LEDS000030 |
Agilent Technologies |
Insight100 |
INS100-v1.0 |
Measurement Software: 1.9.0 |
n/a |
n/a |
INS100-25-EN Revision 2.5 |
3 (B) |
EU Stamp |
|
LEDS000031 |
FLIR |
FIDO X3C |
X3 (PNO.: FH-65-A) |
Measurement Software: Beta 1.00 Build 319 |
n/a |
n/a |
FIDO X3C Administrator Manual 1.00 Rev A (June 2013) |
2 (A) |
EU Stamp |
|
LEDS000032 |
Kromek |
Identifier BLS-1006 |
SPF-TEC-1207 |
7.5.0.10 |
n/a |
BOM-OPS-1006 |
CON-OPS-0866 Rev3 |
3 (B) |
EU Stamp |
|
LEDS000033 |
Kromek |
Identifier BLS-1006 |
SPF-TEC-1207 |
7.5.0.9 |
n/a |
BOM-OPS-1006 |
CON-OPS-0866 Rev3 |
3 (B) |
EU Stamp |
|
LEDS000034 |
Kromek |
Identifier BLS-1006 |
SPF-TEC-1207 |
7.5.0.8 |
n/a |
BOM-OPS-1006 |
CON-OPS-0866 Rev3 |
2 (B) |
EU Stamp |
|
LEDS000035 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
06-60-32 |
n/a |
Schoeller Allibert tray 2A021 |
95593780, 30/03/2012 |
2 (C) |
EU Stamp |
|
LEDS000036 |
Agilent Technologies |
Insight100 |
INS100-v1.0 |
Measurement Software: 1.9.0 |
n/a |
n/a |
INS 100-25-EN Rev. 2.5 INS100-24-EN Rev. 1.1 |
3 (A) |
EU Stamp |
|
LEDS000037 |
Leidos |
ACX6.4-MV (3 view) with Optosecurity XMS® |
1000-MVACX-03 REV:C0 |
V 6.7 |
n/a |
HP Z620 (OS-3000, 5.12) |
8500-10118-00 REV:A1 |
2 (C) |
EU Stamp |
|
LEDS000038 |
Nuctech |
RT1003 |
3.0 |
1.0.9.6 |
n/a |
n/a |
7.1.1 |
2 (B) |
EU Stamp |
|
LEDS000039 |
Optosecurity |
OptoScreener on Smiths 6040i |
Smiths 6040i |
V 6.0 |
n/a |
HP Z620 (OS3000 – 5.33) |
D500-10001 |
2 (C) |
EU Stamp |
|
LEDS000040 |
Optosecurity |
OptoScreener on Smiths 6040i |
Smiths 6040i |
V 6.0 |
n/a |
HP Z620 (OS3000 - 6.8.1) |
D500-10001 |
2 (C) |
EU Stamp |
|
LEDS000041 |
Optosecurity |
OptoScreener on Smiths 6046si |
Smiths 6046si |
V 6.5 |
n/a |
HP Z620 / OS3000 |
D500-10001 |
2 (C) |
EU Stamp |
|
LEDS000042 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
07-60-30 |
n/a |
Schoeller Allibert tray 2A021 |
95593780, 30/03/2012 |
2 (C) |
EU Stamp |
|
LEDS000043 |
Battelle |
LS10 |
LS10 (635109J5000-10) |
v1.3.32.1613 v1.3.40.1614 |
n/a |
Firmware v1.24 |
LS10 Operator Manual (635109J0040) |
3 (B) |
EU Stamp |
|
LEDS000044 |
Emisens |
EMILI |
EMILI TS |
Measurement Software: ecac_std_v5.1.ini ecac_std_v5.2.ini ecac_std_v5.3.ini |
n/a |
n/a |
EMILI TS Conops 0513 |
2 (B) |
EU Stamp |
|
LEDS000045 |
Nuctech |
LS1516BA |
DHV 1.0 |
AV 3.2.1.11 AV 3.2.1.12 |
V1.2.036.188 |
n/a |
2010-06-01 V1-C |
3 (B) |
EU Stamp |
|
LEDS000046 |
Osaka University |
NuLEDS 1.0 |
Nu-1.0 |
Nu-1.0 |
n/a |
No tray |
Nu-1.0 2013-11-06 |
2 (B) |
EU Stamp |
|
LEDS000047 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
08-12-30 |
n/a |
n/a |
95584650, 15/09/2013 |
2 (C) |
EU Stamp |
|
LEDS000048 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
08-12-35 |
n/a |
n/a |
95584650, 15/09/2013 |
2 (C) |
EU Stamp |
|
LEDS000049 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
06-31-37 |
n/a |
Herbert Tray 91280AS |
95594586, 22/11/2013 |
2 (C) |
EU Stamp |
|
LEDS000050 |
Smith’s Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
06-31-37 |
n/a |
MacDonald Humfrey Tray |
95594586, 22/11/2013 |
2 (C) |
EU Stamp |
|
LEDS000051 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
06-31-38 |
n/a |
Herbert Tray 91280AS |
95594585, 22/11/2013 |
2 (C) |
EU Stamp |
|
LEDS000053 |
CEIA |
EMA-3 |
EMA-3 |
PV EMA3 3550, PVCT EMAO 2100, AL3 |
n/a |
n/a |
FI200K0015v1122 |
2 (B) |
EU Stamp |
|
LEDS000054 |
CEIA |
EMA-3 |
EMA-3 |
PVCT EMAO 2100, PVEX EMAX 5311 |
n/a |
EMA-EXTP-EXA-MS |
FI200K0015v1209 |
3 (A) |
EU Stamp |
|
LEDS000055 |
Nuctech |
RT1003 |
3.0 |
Measurement Software: 1.0.9.12 |
n/a |
n/a |
7.1.1 |
3 (B) |
EU Stamp |
|
LEDS000056 |
Nuctech |
XT2080 X-Ray CT |
CH-II 1.2 |
LEDS 1.7 |
n/a |
n/a |
V1.1 |
2 (D) / (D+) |
EU Stamp |
|
LEDS000057 |
Gilardoni |
FEP ME 640 |
37493500-000 |
3AUE0263-002 |
3AUE0217 |
n/a |
37493700-003 |
2 (C) |
EU Stamp |
|
LEDS000058 |
Gilardoni |
FEP ME 640 AMX |
37548400-000 |
3AUE0263-002 |
3AUE0183-002 |
n/a |
37548500-001 |
2 (C) |
EU Stamp |
|
LEDS000059 |
One Resonance Sensors |
MobiLab® BLS |
MobiLab® BLS |
Measurement Software: 2.01B YM BLS 1402 |
n/a |
n/a |
MobiLab®BLS-Configuration A, February 5th, 2014 |
2 (B) |
EU Stamp |
|
LEDS000060 |
Agilent Technologies |
Insight100 |
INS100-v1.0 |
Measurement Software: 1.9.0 |
Auxiliary Measurement Software: 1.2.0, Grav200.exe (1.0) |
Grav-kit-v1.0 |
INS100-35-EN Revision 1.0 |
3 (B) |
EU Stamp |
|
LEDS000061 |
Nuctech |
LS1516BA |
DHV 1.0 |
AV 3.2.2.0 AV 3.2.2.1 |
V1.2.036.200 |
n/a |
2010-06-01 V1-C |
3 (B) |
EU Stamp |
|
LEDS000062 |
Nuctech |
LS1516BA |
DHV 1.0 |
AV 3.2.2.0 AV 3.2.2.1 |
V1.2.036.200 |
n/a |
2013-11-06 V2-B |
2 (C) |
EU Stamp |
|
LEDS000063 |
CEIA |
EMA-3 |
EMA-3 |
PV EMA33550, PVCT EMAO 2100, AL4 |
n/a |
n/a |
FI200K0015v1122 |
3 (B) |
EU Stamp |
|
LEDS000064 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
08-13-30 |
n/a |
n/a |
95584650, 15/09/2013 |
2 (C) |
EU Stamp |
|
LEDS000065 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
08-14-40 |
n/a |
n/a |
95584650, 15/09/2013 |
3 (C) |
EU Stamp |
|
LEDS000066 |
Gilardoni |
FEP ME 640 |
37493500-000 |
3AUE0263-002 |
3AUE0217-001 |
n/a |
37493700-003 |
2 (C) |
EU Stamp |
|
LEDS000067 |
Nuctech |
RT1003E |
2.0 |
1.1.2 |
n/a |
n/a |
3.1 |
3 (B) |
EU Stamp |
|
LEDS000068 |
Rapiscan |
620 DV |
620DV |
3.280 |
n/a |
MacDonald Humfrey Tray (42112481) Herbert Tray (P/N 42112482) |
92106913 rev 2 |
2 (C) |
EU Stamp |
|
LEDS000069 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
08-51-33 |
n/a |
CQRTS ST-14 Tray |
95595576, 18/03/2015 |
2 (C) |
EU Stamp |
|
LEDS000070 |
Gilardoni |
FEP ME 640 |
37493500-001 |
3AUE0263-003 |
3AUE0217-001 |
n/a |
37620800-001 |
2 (C) |
EU Stamp |
|
LEDS000071 |
Gilardoni |
FEP ME 640 AMX |
37548400-001 |
3AUE0263-003 |
3AUE0183-002 |
n/a |
37620900-001 |
2 (C) |
EU Stamp |
|
LEDS000072 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
08-51-33 |
n/a |
CQRTS ST-15 Tray |
95595576, 18/03/2015 |
2 (C) |
EU Stamp |
|
LEDS000073 |
Emisens |
EMILI 3 |
EMILI 3 |
Measurement Software: ecac_std_v6.1.ini |
n/a |
n/a |
EMILI 3 Conops 1214 (Rev. 1 March 2015) |
2 (B) |
EU Stamp |
|
LEDS000074 |
Emisens |
EMILI 3 |
EMILI 3 |
Measurement Software: ecac_std_v6.13.ini ecac_std_v6.14.ini |
n/a |
n/a |
EMILI 3 Conops 1214 (Rev. 1 March 2015) |
3 (B) |
EU Stamp |
|
LEDS000075 |
Agilent Technologies |
Insight200M |
Cobalt P/N 071-T008-201 |
SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) Gravi200.exe (1.1) Gravi200.DLL (1.1) |
n/a |
n/a |
INS200M - 25 - EN Revision 1.1 |
3 (B) |
EU Stamp |
|
LEDS000076 |
Agilent Technologies |
Insight200M |
Cobalt P/N 071-T008-201 |
SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) |
n/a |
n/a |
INS200M - 24 - EN Revision 1.0 used with INS200M – 25 – EN Revision 1.1 |
3 (A) |
EU Stamp |
|
LEDS000077 |
Veriteque USA, Inc |
SwabTek LETK |
Test strip 082015V2 |
n/a |
n/a |
n/a |
LETK082015 v2.0 LETK072016 v3.0 |
2 (A) |
EU Stamp |
|
LEDS000078 |
Leidos |
ClearScan |
1000-10001-CS Rev 01 |
EDS-1.1.1 |
n/a |
Scarabee Long Tray |
8100-26903-00 |
2 (D) / (D+) |
EU Stamp |
|
LEDS000079 |
Leidos |
ClearScan |
1000-10001-CS Rev 01 |
EDS-1.1.1 |
n/a |
Herbert Tray |
8100-26903-00 |
2 (D) / (D+) |
EU Stamp |
|
LEDS000080 |
Battelle |
LS10 |
LS10 (635109J5000-10) |
v2.3.40.1705 |
n/a |
Firmware v1.24 |
LS10 Operator Manual (635109J0040) |
3 (B) |
EU Stamp |
|
LEDS000081 |
Battelle |
LS10 |
LS10 (635109J5000-10) |
v2.2.14.001 |
n/a |
Firmware v1.24 |
LS10 Operator Manual (635109J0040) |
2 (B) |
EU Stamp |
|
LEDS000082 |
Gilardoni |
FEP ME 640 AMX |
37548400-001 |
3AUE0263-004 |
3AUE0183-002 |
Gilardoni Tray 10461200 |
37637700-001 rev 002 |
2 (C) |
EU Stamp |
|
LEDS000083 |
Kumahira Co. Ltd. |
LSR-M1 |
1.0 |
1.0 |
n/a |
No tray |
2015/09/26 v1.0 |
2 (B) |
EU Stamp |
|
LEDS000084 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
09-12-30 |
n/a |
Herbert Tray 91280AS |
95594585, 24/11/2015 |
2 (C) |
EU Stamp |
|
LEDS000085 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
08-90-30 |
n/a |
Schoeller Allibert tray 2A021 |
95593780, 30/03/2012 |
2 (C) |
EU Stamp |
|
LEDS000086 |
Smiths Detection |
HI-SCAN 6040aTiX |
HI-SCAN 6040aTiX 91290001 |
08-90-31 09-12-23 |
n/a |
Schoeller Allibert tray 2A021 |
95593780, 30/03/2012 |
3 (C) |
EU Stamp |
|
LEDS000087 |
Nuctech |
RT1003EB |
2.0 |
1.1.3 |
n/a |
n/a |
2.1 |
3 (B) |
EU Stamp |
|
LEDS000088 |
Nuctech |
RT1003EB |
2.0 |
1.1.3 |
n/a |
n/a |
2.1 |
3 (A) |
EU Stamp |
|
LEDS000089 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-12-26 |
n/a |
Schoeller Allibert Tray 2A021 |
95593780, 30/03/2012 |
3 (C) |
EU Stamp |
|
LEDS000090 |
DetectaChem |
SEEKERe |
2.5.1 |
13.1.0 |
n/a |
n/a |
SEEKERe User Manual (R1.10) |
2 (A) |
EU Stamp |
|
LEDS000091 |
DetectaChem |
SEEKERe |
2.5.1 |
13.2.2 |
n/a |
n/a |
SEEKERe User Manual (R1.10) |
2 (A) |
EU Stamp |
|
LEDS000092 |
DetectaChem |
SEEKERe |
2.5.1 |
13.3.0 |
n/a |
n/a |
SEEKERe User Manual (R1.10) |
2 (A) |
EU Stamp |
|
LEDS000093 |
Kumahira Co. Ltd. |
LSR-M2 |
1.00 |
1.00 |
1.00 |
NIR.DB.ECAC.1.0.0.0 |
1.00 |
3 (B) |
EU Stamp |
|
LEDS000094 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
09-15-19 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
2 (C) |
EU Stamp |
|
LEDS000095 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
09-15-20 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
2 (C) |
EU Stamp |
|
LEDS000096 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
09-15-18 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
2 (C) |
EU Stamp |
|
LEDS000097 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
08-90-31 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000098 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-13 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000099 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-16-23 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000100 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
08-90-31 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000101 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-13 |
n/a |
Herbert Tray 91280AS (P/N 34460688) |
95594585 (22/11/2013) |
3 (C) |
EU Stamp |
|
LEDS000102 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-16-23 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000103 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-15-16 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000104 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-15-25 |
n/a |
Herbert tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000105 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-15-25 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000106 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-16-26 |
n/a |
Schoeller Allibert tray 2A021 (P/N 11112352) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000107 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-17-16 |
n/a |
Herbert tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000108 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-17-26 |
n/a |
Herbert tray 91280AS (P/N 34460688) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000109 |
Kumahira Co. Ltd. |
LSR-M2 |
1.01 |
1.00 |
1.01 |
NIR.DB.ECAC.1.0.0.0 |
CONOP v1.00 |
3 (B) |
EU Stamp |
|
LEDS000110 |
Nuctech |
RT1003EB |
2.0 |
1.1.3 |
n/a |
n/a |
2.2 |
3 (B) |
EU Stamp |
|
LEDS000111 |
Nuctech |
RT1003EB |
2.0 |
1.1.3 |
n/a |
n/a |
2.2 |
3 (A) |
EU Stamp |
|
LEDS000112 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
09-15-20 |
n/a |
Smiths Detection Tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) |
95595885 (2016/09/26) |
2 (C) |
EU Stamp |
|
LEDS000113 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-16-23 |
n/a |
Smiths Detection Tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000114 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-18-13 |
n/a |
MacDonald Humfrey Tray (P/N 34460689) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000115 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-18-24 |
n/a |
MacDonald Humfrey Tray (P/N 34460689) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000116 |
Kumahira Co. Ltd. |
LSR-M2 |
1.01 |
1.00 |
1.02 |
NIR.DB.ECAC.1.0.0.0 |
CONOP v1.01 (24/04/2018) |
3 (B) |
EU Stamp |
|
LEDS000117 |
Nuctech |
CX6040D |
CX6040D.B05N |
Lida V1.0.1 |
n/a |
LTray V1.0 |
CONOPS CX6040D V1.0 (2017-12-01) |
2 (C) |
EU Stamp |
|
LEDS000118 |
Kumahira Co. Ltd. |
LSR-M2 |
1.01 |
1.00 |
1.03 |
NIR.DB.ECAC.1.0.0.0 |
CONOP v1.01 (24/04/2018) |
3 (B) |
EU Stamp |
|
LEDS000120 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
08-90-31 |
n/a |
Smiths Detection tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000121 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
09-19-19 |
n/a |
Vanderlande tray (P/N P10128 / 095527-727) Vanderlande inlay (P/N P13715 / 095535-212) |
95596016 (2017/09/26) |
2 (C) |
EU Stamp |
|
LEDS000122 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-15-13 |
n/a |
Smiths Detection tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000123 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-19-23 |
n/a |
Vanderlande Scannojet tray (P/N P10128 / 095527-727) |
95595885 (2016/09/26) |
3 (C) |
EU Stamp |
|
LEDS000124 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-70-23 |
n/a |
Vanderlande Scannojet tray (P/N P10128 / 095527-727) |
95596016 |
3 (C) |
EU Stamp |
|
LEDS000125 |
Kumahira Co. Ltd. |
LSR-M2 |
1.01 |
1.01 |
V 2.00 V 2.01 V 2.10 V 2.20 V 2.30 |
NIR. DB. ECAC 1.0.0.0 No tray |
v1.02 |
3 (B) |
EU Stamp |
|
LEDS000126 |
Kumahira Co. Ltd. |
LSR-M2 |
1.01 |
1.01 |
V 2.00 V 2.01 V 2.10 V 2.20 V 2.30 |
NIR. DB. ECAC 1.0.0.0 No tray |
v1.02 |
3 (A) |
EU Stamp |
|
LEDS000127 |
Smiths Detection |
HI-SCAN 7555aTiX |
HI-SCAN 7555aTiX 91460001 |
09-16-26 |
n/a |
Smiths Detection Tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) |
95596016 (2017/09/26) |
2 (C) |
EU Stamp |
|
LEDS000128 |
X-Ray Center |
XRC 60-40DV |
n/a |
108.1.117.187.21 |
n/a |
tray: Elder engineering (P/N 42106376) Foam (Polyformes, P/N 256412) Bolts (RS components, P/N 12234438) |
MCIL Rev.1 |
2 (C) |
EU Stamp |
|
LEDS000129 |
X-Ray Center |
XRC 60-40DV |
n/a |
108.1.117.187.25 |
n/a |
tray: Elder engineering (P/N 42106376) Foam (Polyformes, P/N 256412) Bolts (RS components, P/N 12234438) |
MCIL Rev.1 |
2 (C) |
EU Stamp |
|
LEDS000130 |
X-Ray Center |
XRC 60-40DV |
n/a |
108.1.117.187.35 |
n/a |
tray: Elder engineering (P/N 42106376) Foam (Polyformes, P/N 256412) Bolts (RS components, P/N 12234438) |
MCIL Rev.1 |
3 (C) |
EU Stamp |
|
LEDS000131 |
Veriteque USA, Inc |
SwabTek LETK |
Test strip batch BL 315250 |
n/a |
n/a |
n/a |
LTD 29 November 2018 v2.0 |
3 (A) |
EU Stamp |
|
LEDS000132 |
Nuctech |
CX 7555D |
CX7555D.A03N |
Lida V1.0.2 |
n/a |
Tray: LTray V1.0 |
CONOPS_CX7555D_LEDS_V 1.0_20190716 |
2 (C) |
EU Stamp |
|
LEDS000134 |
Rapiscan |
620 DV |
n/a |
3.500; 3.520 |
n/a |
Vanderlande Scannojet tray (P/N P10128 / 095527-727) |
92106913, Rev 2 |
2 (C) |
EU Stamp |
|
LEDS000135 |
Agilent Technologies |
Insight200M |
Agilent G6913A with Cobalt internal P/N 071-T008-201 |
SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) Gravi200.exe (1.1) Gravi200.DLL (1.1) |
n/a |
n/a |
Type B PLRM-CUD22 Insight200M CONOPS Rev 2.0 |
3 (B) |
EU Stamp |
|
LEDS000136 |
Agilent Technologies |
Insight200M |
Agilent G6913A with Cobalt internal P/N 071-T008-201 |
SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) |
n/a |
n/a |
Type A PLRM-CUD21 Insight200M CONOPS Rev 2.0 |
3 (A) |
EU Stamp |
|
LEDS000137 |
Smiths Detection |
HI-SCAN 6040aTiX |
6040aTiX |
09-16-23 |
n/a |
Smiths Detection tray 3 (P/N 34495374, with Safety-Walk + RFID-Tag + Liquidinlay) |
95596016 rev. 02 (2020/03/01) |
2 (C) |
EU Stamp |
|
LEDS000138 |
Smiths Detection |
HI-SCAN 7555aTiX |
7555aTiX |
09-71-27 |
n/a |
Smiths Detection Tray (P/N 34486990) |
95596016 (2017/09/26) |
2 (C) |
EU Stamp |
|
LEDS000139 |
Smiths Detection |
HI-SCAN 6040-2is HR |
HI-SCAN 6040-2is HR 90140002 |
09-15-20 |
n/a |
Smiths Detection tray 3 (P/N 34495374, with Safety-Walk + RFID-Tag + Liquidinlay) |
95596016 rev. 02 (2020/03/01) |
3 (C) |
EU Stamp |
|
LEDS000140 |
CEIA |
EMA-4 |
EMA-4 |
ALG1 |
n/a |
n/a |
FI200K048v1000hUK |
3 (B) |
EU Stamp |
|
LEDS000141 |
Smiths Detection |
HI-SCAN 6040 DV |
6040 DV |
30-00-18 |
n/a |
Smiths Detection tray 2 (P/N 34482148) Smiths Detection tray 3 (P/N 34495374, with Safety-Walk + RFID-Tag + Liquidinlay) |
95596016 rev. 02 (2020/03/01) |
2 (C) |
EU Stamp |
|
LEDS000142 |
Rapiscan |
920DX |
920DX |
1.9 |
n/a |
Herbert tray (P/N 42112482) |
D05354 |
3 (C) |
EU Stamp |
|
LEDS000143 |
Rapiscan |
920DX |
920DX |
2.01 |
n/a |
Vanderlande tray (P/N 095527-727) |
D05354 |
3 (C) |
EU Stamp |
|
LEDS000144 |
Rapiscan |
920DX |
920DX |
2.02 |
n/a |
MacDonald Humfrey tray (P/N 101005244) |
D05354 |
3 (C) |
EU Stamp |
|
LEDS000145 |
Smiths Detection |
HI-SCAN 6040 DV |
6040 DV |
30-00-29 |
n/a |
Vanderlande Scannojet (P/N 10128 /095527-727) |
95596016 rev. 02 (2020/03/01) |
2 (C) |
EU Stamp |
|
LEDS000146 |
Veriteque USA, Inc |
SwabTek LETK |
LTD Gen 2 |
n/a |
n/a |
n/a |
LTD Gen 2 v1.1 |
3 (A) |
EU Stamp |
|
LEDS000147 |
Nuctech |
Kylin MV |
DHV 1.0 |
7.1.3 |
n/a |
Nuc680 Tray (P/N v3) Nuc680 Tray (P/N v5) |
EDSCB and LEDS V2.0 |
3 (C) |
EU Stamp |
|
LEDS000148 |
Nuctech |
CX6040D |
CX6040D.B07N |
Lida V1.0.4 |
n/a |
STL-Tray V1.0; L-Tray V1.0 |
CONOPS_CX6040D_V1.0_LEDS |
2 (C) |
EU Stamp |
|
LEDS000149 |
Nuctech |
CX6040D |
CX6040D.B07N |
Lida V1.0.5 |
n/a |
STL-Tray V1.0; L-Tray V1.0 |
CONOPS_CX6040D_V1.0_LEDS |
3 (C) |
EU Stamp |
|
LEDS000150 |
CEIA S.p.A |
EMA-4 |
EMA-4 |
ALG11; ALG12; ALG13 |
n/a |
n/a |
FI200K0048v1001hUK |
3 (B) |
EU Stamp |
|
LEDS000151 |
Kumahira Co. Ltd. |
LSR-M3 |
1.00 |
1.00 |
n/a |
n/a |
ConOps_LSR-M3v1.01 |
2 (B) |
EU Stamp |
|
LEDS000152 |
Nuctech |
RT1003EB |
3.0 |
2.0 |
n/a |
n/a |
RT1003EB CONOPS V3.0 |
3 (A) |
EU Stamp |
|
LEDS000153 |
Kumahira Co. Ltd. |
LSR-M2-CSE |
1.01 |
1.11; 1.12 |
1.00 |
n/a |
LSR-M2-CSE Ver2.1 |
3 (B) |
EU Stamp |
|
LEDS000154 |
Kumahira Co. Ltd. |
LSR-M3 |
1.00; |
1.10; 1.11; 1.12 |
1.01 |
n/a |
ConOps_LSR-M3v1.01 |
3 (B) |
EU Stamp |
|
LEDS000155 |
Leidos |
PX 640 |
37493500-001 |
3AUE0263-003 |
n/a |
n/a |
37620800-001 |
2 (C) |
EU Stamp |
|
LEDS000156 |
Leidos |
PX 640 DV |
37548400-001 |
3AUE0263-003 |
n/a |
n/a |
37620900-001 |
2 (C) |
EU Stamp |
|
LEDS000157 |
Agilent Technologies |
Insight300M |
G6930A |
SORS: 1.1.0.25 Gravimetric: 1.0.0.13 Item Screenability:10.00.00 Model DB: 10.0.1 Metal DB: 10.02.00 |
Insight exe: 4.5.1870 Agilent Service: 1.9.0.8 |
n/a |
G6930-90002 A.01 |
3 (B) |
EU Stamp |
|
LEDS000158 |
Agilent Technologies |
Insight300M |
G6930A |
SORS: 1.1.0.25 Gravimetric: 1.0.0.13 Item Screenability:10.00.00 Model DB: 10.0.1 Metal DB: 10.02.00 |
Insight exe: 4.5.1870 Agilent Service: 1.9.0.8 |
Vial holder: G6923-52009 Vials: 5188-5392 |
G6930-90000 A.02 |
3 (A) |
EU Stamp |
8. MODHANNA SCAGTHA LENA nÚSÁIDTEAR TEICNEOLAÍOCHTAÍ NUA
Fágtha bán d’aonghnó
9. MADRAÍ BRAITE PLÉASCÁN
Fágtha bán d’aonghnó
10. TREALAMH BRAITE MIOTAIL (MDE)
Réimse úsáide: Lastas
|
Aitheantóir uathúil |
Monaróir |
Ainmníocht |
Cumraíocht mhionsonraithe |
Caighdeán |
Stádas |
||||
|
Crua-earraí |
Algartam braite |
Bogearraí córais |
Crua-earraí tánaisteacha |
Coincheap na n-oibríochtaí |
|||||
|
MDE0000001 |
CEIA |
EMIS 8075 |
EMIS_8075_002 |
EMIS STD with configurations GOODS 1 and GOODS 2 |
SCD V5.800 ALM V5.720 |
n/a |
FI210K0010v1000 |
Yes |
EU Stamp |
|
MDE0000002 |
CEIA |
EMIS 130160 |
EMIS_130160_002 |
EMIS STD with configurations GOODS 1 and GOODS 2 |
SCD V5.800 ALM V5.720 |
n/a |
FI210K0008v1000 |
Yes |
EU Stamp |
|
MDE0000003 |
CEIA |
EMIS 130200 |
EMIS_130200_002 |
EMIS STD with configurations GOODS 1 and GOODS 2 |
SCD V5.800 ALM V5.720 |
n/a |
FI210K0008v1000 |
Yes |
EU Stamp |
11. SCANÓIRÍ SLÁNDÁLA
Ar bhonn choincheap na n-oibríochtaí arna soláthar ag an monaróir, rinneadh feidhmiú an scanóra slándála a thástáil le haghaidh cineál áirithe oibríochtaí:
|
— |
Ciallaíonn (A) scanóir slándála lenar féidir bagairt a bhrath go huathoibríoch agus lena dtaispeántar, ar íomhá d’fhear cipíní, suíomh na n-earraí arna mbrath.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12. TREALAMH SCANÓRA BRÓG
12.1 Trealamh Braite Miotail le hAghaidh Bróg (SMD)
Gan iontráil.
12.2 Trealamh Braite Pléascán le hAghaidh Bróg (SED)
Gan iontráil.
13. BOGEARRAÍ BRAITE UATHOIBRITHE ÍTIMÍ TOIRMISCTHE (APID)
Tagraíonn an colún ‘Monaróir’ d’fhorbróir bunaidh na mbogearraí APID.
I gcás nach ionann forbróir na mbogearraí agus an monaróir trealaimh, tugtar an monaróir trealaimh le fios le OEM (Monaróir Buntrealaimh).
|
Aitheantóir uathúil |
Monaróir |
Ainmníocht |
Cumraíocht mhionsonraithe |
Caighdeán |
Stádas |
||||
|
Crua-earraí |
Algartam braite |
Bogearraí córais |
Crua-earraí tánaisteacha |
Coincheap na n-oibríochtaí |
|||||
|
APID000001 |
SeeTrue (OEM: Analogic/ Rapiscan) |
ConneCT/ 920CT |
ConneCT; 920CT |
SeeTrue APIDS 41.11.0 |
n/a |
Vanderlande tray (P/N 095527-727) Leidos/MacDonald Humfrey tray (P/N 12043-SLT); Rapiscan/Herbert tray (P/N 101019470) |
Rapiscan 920CT - APIDS Test ConOps V1.1 Jan 17 2023 |
1 |
EU Stamp |
|
APID000002 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-72-11 |
n/a |
Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (P/N 34496512); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373); MacDonald Humfrey tray (P/N 34460689) |
95596016 |
1 |
EU Stamp |
|
APID000003 |
Smiths Detection |
HI-SCAN 6040 CTiX |
6040 CTiX; 6040 CTiX Model S |
20-78-41 |
n/a |
Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (P/N 34496512); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373); MacDonald Humfrey tray (P/N 34460689) |
95596016 |
1 |
EU Stamp |
14. Trealamh BRAITE GAILE PLÉASCAÍ (EVD)
Gan iontráil.
ELI: http://data.europa.eu/eli/dec/2026/2404/oj